10.Multi-Hold Mode
54
10-3-6. Time Specified Hold (Peak, Valley, P-P)
The hold detection period is within the set time (Hold Detect Time) from the triggered
point in time by this method. A reset signal (T/H) is required for canceling the hold.
Example: Time Specified Peak Hold
t1: Delay time between the instant when the H/M signal is input and the instant when the
hold is detected.
Ts+0.8msec (max.)
t2: Delay time between the instant when the hold detect time expires and the instant
when the hold is determined.
Ts+0.8msec (max.)
t3: Minimum reset signal width required for canceling the hold.
Ts+0.8msec (min.)
Determination
Indicated value
Sensor input value
Hold period
Detection
period
t3
t
+
COMPLETE
t2
t1
H/M
T/H
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Hold Detect
Time
High/Low
Limit
Output
Judgment