AC-2100 User Guide
40
lock is not connected.
After selecting a setting value, press down [F4] button for a longer period of
time to continue setting.
3.5.3.2. Door Open Status Check
◆
At default screen [F3~]
[3.Option]
[3.Set Doorlock]
[F4~]
◆
<Door Monitor>
0.None
1.Normal Open
2.Normal Close
[ESC][
↑
][
↓
][ENT]
Default setting: ‘0’
- ‘0.None’: In case door status is not checked
- ‘1.Normal Open’: In case of dead bolt type or automatic door
(In case lock monitoring is open when the door is locked)
- ‘2.Normal Close’: In case of strike type
(In case lock monitoring is close when the door is locked)
Select ‘0’ for no setting, ‘1’ for dead bolt type or automatic door and ‘2’ for strike
type. In case it is set to ‘1’ or ‘2’, information of the door connected to the
terminal is sent to the server periodically.
After selecting a setting value, press [ENT] button to continue setting.
3.5.3.3 Door Open Alarm Setting
Door Open Alarm
(00-30):0
0
[
←
] [
↑
] [
↓
] [
→
]
Default setting: ‘00’
The terminal checks how long the door is opened. This function issues an
alarm if the door is opened for a duration that exceeds the time in setting
(Min. 5seconds ~Max. 30 seconds).
If it is set to ‘00’, an alarm is issued. Even if it is set to 01~04, an alarm is
issued after at least 5 seconds are elapsed.
UNIONCOMMUNITY Co., Ltd. / 3F Hyundai Topix Bldg. 44-3 Bangi-dong Songpa-gu
Seoul, Korea (138-050)
Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr
http://www.unioncomm.co.kr
The door should be locked within the time in setting but the door may not be
locked due to unforeseen circumstances. In such a case, an alarm is issued to
determine the cause of a problem and take the necessary measures to ensure