Sub-menu
Description
Value
1.7.10 Fan control
Select the operational mode of the refrigeration unit’s fan:
•
Always ON – working always
•
Only when cooling – works only when in cooling mode
•
Cooling and defrosting – works when cooling and de-freez-
ing
Always on
Only cooling
Cooling & defrosting
1.7.11 Temp events
Set range of monitored values for temperature sensors
1.7.11.1 Temp 1 min
Set minimum temperature for sensor 1, upon reaching which
the event is logged
Enter
temperature
-10...+60
1.7.11.2 Temp 1 max
Set maximum temperature for sensor 1, upon reaching which
the event is logged
Enter
temperature
-10...+60
1.7.11.3 Temp 2 min
Set minimum temperature for sensor 2, upon reaching which
the event is logged
Enter
temperature
-10...+60
1.7.11.4 Temp 2 max
Set maximum temperature for sensor 2, upon reaching which
the event is logged
Enter
temperature
-10...+60
1.7.11.5 Temp 3 min
Set minimum temperature for sensor 3, upon reaching which
the event is logged.
Enter
temperature
-10...+60
1.7.11.6 Temp 3 max
Set maximum temperature for sensor 3, upon reaching which
the event is logged.
Enter
temperature
-10...+60
1.7.11.7 Fresh temp. timeout Maximal temperature sensor 1 out of range duration (in min-
utes)
Enter number
0...65000
1.7.12 Optical sensor
Configures optical sensors, used to record the dispensing of
products
No
Yes - to sub-menu
1.7.12.1 Max failure
Set the number of failures in attempting to dispense the prod-
uct from all cells in the Machine, upon reaching this number the
Machine reacts as per the settings in s.c.1.7.12.1.1
Enter number
0...255
0-turns OFF
the option
1.7.12.1.1
Max failure option
The Machine’s reaction to failures set in s.c.1.7.12.1:
•
Machine block – restrict sales from all the cells;
•
Disable refund – No refund of deposited credit
Machine block
Disable refund
1.7.12.2 Max sel. failure
Set the maximum number of failures to dispense product from
a single cell.
Upon reaching this number the Machine reacts, as per the set-
tings of 1.7.12.2.1
Enter number
from 0…255
0=Disable option
1.7.12.2.1
Max failure option
Machine’s actions upon reaching the maximum number of
failed attempts at dispensing the product set in s.c.1.7.12.2:
•
Machine block – stop sales from the given cell;
•
Disable refund – no refund of credit deposited
Machine block
Disable refund
1.7.12.3
Additional turn max
Maximum additional turn of spiral in case of failure (to dispense
product)
1/2
3/8
1/4
1/8
1.7.12.4
Additional turn step
The step of additional turn of spiral monitored by the optical
sensors
1/2
1/4
1/8