MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
Revision 2019-07
1.
Maintenance
6
W
Remove the power supply or switch off the main switch before all
maintenance and service work.
Please note!
Only use original spare parts for maintenance and repairs.
Ensure that the warning stickers present and the lights on the URS500 are clearly visible at all times so that they
can alert the URS500 users to safe use.
Please note!
Never repair the URS500 yourself, use a recognized expert for this. Please contact your supplier. If
returning your URS500 device for repair, the boiler must be empty, otherwise your repair cannot be processed.
1.1. Periodic maintenance
Before each use:
• Keep the area around the URS500 clean and free of debris.
• Check the outside and inside of the URS500 for visible damage. Do not turn on the URS500 if you have
detected any damage.
• Check the lid gasket for damage. A damaged lid gasket leads to poor sealing and vapour leakage, which is
dangerous and wasteful.
• Inspect the cooling air outlet and inlet and ensure that there is sufficient space for unobstructed ventilation.
Vacuum clean, if necessary.
• Check the tank for residue and remove it.
• Wipe the top edge of the tank before closing the lid and make sure it is free from paint and contaminated
solvent.
Every month:
• Inspect the power cable for wear and damage. If replacement is necessary, the replacement should be
carried out by a competent installer for explosion proof equipment.
• Clean the condenser: refer to section 4.2 ‘cleaning the condenser’.
• Clean the cap of the condenser block. Refer to section 4.4 ‘Cleaning the condenser discharge tube” .
Every 3 months:
• Run two recycling processes with 5 gallons of clean solvent to keep the condenser discharge tube and the
condenser clean.
Every 6 months:
• Replace the lid gasket preventively.