15
MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
Revision 2019-07
Condenser fins
Cooling air outlet
Cooling air inlet
1.2. Cleaning the condenser
The condenser must be regularly checked and cleaned to ensure that it is free of dust and waste. Dust
and waste that has collected on the other side of the condenser is not visible in the URS500. If the
condenser overheats due to excessive dust, the process will stop and the LEDs will give the fault code 23
or 24. See section 4.6 "Error codes" of this manual for instructions when these errors are indicated.
To clean the condenser, the dust can be blown away with an air gun, or by using a vacuum cleaner with a
brush attachment.
1.3. Replacing the lid gasket
Please note!
Always use original lid gaskets in the URS500.
To replace the lid gasket, follow these steps:
1. Open the safety cover and the tank lid.
Tank lid
Lid gasket
Figure 2. Tank lid of the URS500
2. Hold the lid open with one hand and remove the damaged lid gasket using a flat screwdriver.
3. Clean the edge of the lid where the lid gasket was with a scuff / abrasive material (non-woven), so
that all contamination is removed before the new lid gasket is introduced.