7
MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
Revision 2019-07
Hoses
:
Connect the end of the hose with the “Solvent
In” label to the “Solvent In” port on the recycler.
Hand tighten. Pass the other end of this hose
through the hole in the back of the gun cleaner
that is marked “Solvent Out” and hand tighten
onto the lid of the “WASH SOLVENT” pail. Con-
nect the hose with the “Solvent Out” label to the
“Solvent Out” port at the back of the recycler
and pass the other end of this hose through the
hole in the gun cleaner that is marked “Solvent
In” and hand tighten onto the lid of the “CLEAN
SOLVENT” pail. Make sure there is no leakage.
Air Supply:
The blue airline and Tee are for use with an
“E” series spray gun cleaner to allow one air
supply to feed both the spray gun cleaner and
the solvent recycler.
Ensure the air supply is
not connected to the spray gun cleaner or
solvent recycler before installation.
Remove the 2 airline connectors from the “T” .
Connect the male port of the “T” to Air Inlet of
the recycler. Connect the Moisture Filter (op-
tional). Connect one end of the blue airline to
the “T”. Connect the other end of the blue air
line to the Air Input of the spray gun cleaner.
SOLVENT PAILS
Inside Gun Cleaner Cabinet
Dirty Solvent Out
Clean Solvent In
1) Transferring Solvent To and From a Spray Gun Cleaner
Dirty Solvent In
Clean Solvent Out
Blue Airline - At-
tach to Tee and
Gun Cleaner
Air Supply Input,
Requires Fitting
(not supplied)
Attach Moisture Filter
(optional) to Air Input
and the Tee to the Filter
(if used) and the Blue
Airline to Tee and Gun
Cleaner. The Air Supply
fi tting is also not sup-
plied.