16
MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
Revision 2019-07
1. Install the new lid gasket by hand, by gradually pressing the ring all the way around with your fingers. It is
important that the ring is placed flat and no deformations are visible.
This can be checked by the horizontal seam on the ring, which must be straight along its entire length. Do
not use tools or sharp objects while installing the new lid gasket as they may damage the gasket.
You have replaced the lid gasket.
2. In order to check the proper functioning of the lid gasket, it is advised to recycle the tank once with ±10
litres of clean water.
1.1. Cleaning the condenser discharge tube
A blockage in the condenser discharge tube can cause solvent to leak out of the URS500.
1. Open the cap of the condenser block. This can be loosened by hand. If this doesn’t work, carefully use a
water pump pliers.
Condenser block
Cap from the
condenser block
Figure 1. The condenser block with cap
2. Check the condenser discharge tube and the opening of the vapour outlet for visible signs of blockage.
Condenser
block
Opening of the
vapour outlet
Figure 2.
The condenser block