1. Clean the cap of the condenser block. It is important that all openings in the cap are free. If a layer of
lacquer / residue is blocking the openings, remove it with a small drill, or allow the cap to soak in thinner
and then scrape the dirt off with a metal pin.
Figure 1.
Cap from the condenser block
2. If the blockage is not in one of these places, then the condenser is probably blocked.
3. Place a cloth over the inlet port located in the tank. The
outlet
tube is located inside the door above the
receiving pail. With a blow gun, blow air through the outlet port. Material in the condenser, if any, will exit