RF Power Supply and Matching Box
4. Functions
25
4-1-6 Caution when using the external control terminal (INTERFACE)
If connecting an inductive load (relay or coil) to the output of the external control terminal, insert a
diode or use a relay with a surge absorbing element so that counter-electromotive force is not
generated.
Counter EMF prevention
diode
+12V
Figure 4-4. Overvoltage protection circuit for transistor output section