4
ULVAC CRYOGENICS INCORPORATED
4. Installation
Follow the steps below to attach the MBD-D to the customer’s display panel using the clamp
kit delivered with the MBD-D.
(1)
As shown in the figure below, insert the MBD-D from the front through the rectangle
cutout on the front panel all the way seated in.
(2)
Attach the fixing bracket on top and bottom,
or left and right sides of the MBD-D
(3)
Fasten the screws to fix the MBD-D.
(4)
Connect the cables included in the package to the MBD-D.
Fixing brackets attached on
the right and left side (2)
Fixing brackets attached
on top and bottom. (2)
92
-0.0, +0.5
45
–0.0, +0.5
(Cutout on the front panel )
Customer’s panel
(1)
(3)
(3)
(Front)
(Inside the panel)
Use a flathead screwdriver to fasten.
OR
Thickness should be 1.0 - 4.0mm