SAMPLE SYSTEM PROGRAMMING
4-35
1. Outline your system.
SmartScan Unit (Ceiling Entrance) = Camera #2.
Monitor in Office = Video Output (Monitor) #1
Alarm (Entrance) = AIU-100 Address 0, Alarm Input #4
VCR in Office = Video Output #2 and Auxiliary Output #1 on HD Series
Switcher
2. Set-up Alarm Monitors and Alarm VCRs
a.
Press Shift F12 on the KBD-100A keyboard.
The following display appears on the screen.
ALARM SETUP
ALARM MONITORS
FIRST -
⋅
⋅
LAST -
⋅
⋅
ALARM VCR VIDEO OUTPUTS
FIRST -
⋅
⋅
LAST -
⋅
⋅
ALARM VCR CNTRL OUTPUTS
FIRST -
⋅
⋅
LAST -
⋅
⋅
b.
Enter 1 for first alarm monitor and 1 for last alarm monitor.
c.
Enter 2 for first alarm VCR video output and 2 for last alarm VCR
video output.