PROGRAMMING MULTICALLS
4-7
The letters of the functions that are programmable are listed at the
bottom of the screen.
Function Descriptions:
P - PreShot
V - VectorScan
M - MultiCall
C - Call (call a camera to a monitor, call a camera to an alarm monitor,
call a camera to an alarm VCR, or automatically acknowledge an
alarm )
A - Auxiliary Output Control On/Off (such as VCRs)
See paragraphs 4.3.3.1 through 4.3.3.5 for the steps required to
program each type of function.
NOTE
When a function is selected, there are messages on the bottom of the screen to
prompt the programmer for the next required field entry.
Enter data in the fields by typing the desired information. The cursor
moves to the next field. If the cursor does not move to the next field,
use the gray right arrow key to move it to the next field.
For example,
Enter P in the FUN field means type the letter P in the column
headed FUN
.
Enter a transit time in the MISC field means type a
number from 0.0 to 9.9 in the column headed MISC.
If data is
entered quickly, the screen prompts may not update until the rate of
entry slows down.
Summary of Contents for CCU-100HD
Page 16: ......
Page 24: ......
Page 31: ...Figure 2 1 MODEL CCU 100 HD or CCU 100 HD X EQUIPMENT BLOCK DIAGRAM...
Page 39: ...Figure 2 3 EQUIPMENT CONNECTIONS FOR CHANNELS 1 2 AND 3 NEAR CLOSE OPEN FAR...
Page 41: ...Figure 2 4 EQUIPMENT CONNECTIONS FOR CHANNELS 4 AND 6...
Page 43: ...Figure 2 5 1 EQUIPMENT CONNECTIONS FOR CHANNEL 5...
Page 44: ...Figure 2 5 2 EQUIPMENT CONNECTIONS FOR CHANNEL 5...
Page 45: ...Figure 2 5 3 EQUIPMENT CONNECTIONS FOR CHANNEL 5...
Page 48: ......
Page 49: ...2 25...
Page 50: ...2 26...
Page 68: ......
Page 112: ......
Page 126: ...A 12 PRESHOT PROGRAMMING LOG Page ___ of ___ CAMERA NUMBER _____ PreShot Name Coverage...
Page 130: ...A 16 AIU 100 ALARM LOG Page ___ of ___ AIU ___ Alarm MultiCall Description of MultiCall...
Page 132: ...A 18 MULTICALL LOG Page ___ of ___ MultiCall Assigned To Description...
Page 146: ......