background image

2

CONTENTS

 section  1

 Components 

list 

2

 section  2

 

Roof vent sash 

3

section 3

 

Vent main frame into roof 

3-4

section 4

 

Fitment of mechanical winder 

4-5

 

Fitment of electric motor (if selected) 

5

section 5

 

Installation of vent controller  

6

 

Optional automatic vent controller 

6

section 6

 

Switch and controller wiring 

7

section 7

 

Installation of rain sensor 

7

section 8

 

Adjustment and testing 

8

section 9

 

Use of controller 

8

TECHNICAL SUPPORT

Tel:  01200 452918    Email: [email protected]

Please read in conjunction with the installation guide provided with the roof itself.

SECTION 1

PVCU ROOF VENT INSTALLATION GUIDE

COMPONENT LIST    DEPENDANT ON ANCILLARIES CHOSEN

SLIMLINE 25MM ROOF VENT

SPINDLE - SLVSP001

SLVTS002-6 - VENT SCREW

AMB 25

EXTERNAL  STANDARD

AMB 32

EXTERNAL  35MM GLAZING

TAPE 

PMB 2

INTERNAL  STANDARD

MOTOR*

White Q8750

Black QBL8750

AVS001 

ROCKER SWITCH*

AVTD002 

THERMOSTAT*

SLRCU003RC 

REMOTE CONTROL*

SLCCU002

THERMOSTAT & DIGITAL 

RAIN SENSOR* 

SLCCU003 

RADIO CONTROL UNIT*

*separate installation guide supplied in box.

ROOF VENT POLE BRPA001

Summary of Contents for ROOF VENT

Page 1: ...V2 August 2019 ROOF VENT INSTALLATION GUIDE...

Page 2: ...NICAL SUPPORT Tel 01200 452918 Email techsupport ultraframe co uk Please read in conjunction with the installation guide provided with the roof itself SECTION 1 PVCU ROOF VENT INSTALLATION GUIDE COMPO...

Page 3: ...above and ensure the tape is directed against section 2 1 SECTION 3 Run a bead of appropriate sealant ensuring a continuous run along the external upper muntin bar Please see section view for bead pos...

Page 4: ...rnal lower muntin bar knock into place The lower muntin may need supporting from underneath whilst secured into final postion 12 Whenthesealantonthemainframehascured re fit the outer sash by holding v...

Page 5: ...ECTION 4 20 Finished mounted motor in situ 17 Using the nuts and bolts provided attach the motor bracket to the sash bracket taking care not to damage the glazed unit 18a 19 Fit provided securing bolt...

Page 6: ...east 3mm in all poles 6 Replace the front panel THIS UNIT TO BE INSTALLED USING BASEC OR HAR APPROVED CABLE AND MUST BE SUITABLY EARTHED NOTE CABLE NOT SUPPLIED BY ULTRAFRAME SECTION 5 INSTALLATION OF...

Page 7: ...ost rainfall comes from the South West This is therefore the preferred side of the roof for the rain sensor but check local conditions especially on the East Coast or on Mainland Europe 15 TO 45 PITCH...

Page 8: ...kept free of grease and sealing compound OPENING ADJUSTMENT Within the opening distance selected at the actuator the opening distance when opening automatically can be adjusted in the range 100 300mm...