4

VENT MAIN FRAME INTO ROOF

SECTION 3 

8

9

Slide the internal lower muntin bar into place 
under the vent frame. See cross section 8a for 
further detail.

Remove any handling tape around the 
perimeter of the unit. Take care lowering the 
glazed unit into position on the internal lower 
muntin bar.

11

Run a bead of appropriate sealant ensuring 
a continuous run along the external lower 
muntin bar. Please see cross section for bead 
positioning.

10

Locate the external lower muntin bar with the 
internal lower muntin bar, knock into place. 
The lower muntin may need supporting from 
underneath whilst secured into 

fi

 nal postion. 

12

When the sealant on the mainframe has cured, 
re-

fi

 t the outer sash by holding vertically and

re-engage on to the hinge, before lowering 
into position.

13

Using the screws provided attach the 
spindle bracket to the sash bracket (already 
attached to vent sash) taking care not to 
damage the glazed unit.

14

Align the winder bracket to the extrusion detail 
(see section detail 14a for further information). 
Centrally align the winder bracket with the 
sash bracket. Once in position securely 

fi

 t 

bracket in place using screws provided. 

FITMENT OF MECHANICAL WINDER

SECTION 4

8a

10a

Summary of Contents for ROOF VENT

Page 1: ...V2 August 2019 ROOF VENT INSTALLATION GUIDE...

Page 2: ...NICAL SUPPORT Tel 01200 452918 Email techsupport ultraframe co uk Please read in conjunction with the installation guide provided with the roof itself SECTION 1 PVCU ROOF VENT INSTALLATION GUIDE COMPO...

Page 3: ...above and ensure the tape is directed against section 2 1 SECTION 3 Run a bead of appropriate sealant ensuring a continuous run along the external upper muntin bar Please see section view for bead pos...

Page 4: ...rnal lower muntin bar knock into place The lower muntin may need supporting from underneath whilst secured into final postion 12 Whenthesealantonthemainframehascured re fit the outer sash by holding v...

Page 5: ...ECTION 4 20 Finished mounted motor in situ 17 Using the nuts and bolts provided attach the motor bracket to the sash bracket taking care not to damage the glazed unit 18a 19 Fit provided securing bolt...

Page 6: ...east 3mm in all poles 6 Replace the front panel THIS UNIT TO BE INSTALLED USING BASEC OR HAR APPROVED CABLE AND MUST BE SUITABLY EARTHED NOTE CABLE NOT SUPPLIED BY ULTRAFRAME SECTION 5 INSTALLATION OF...

Page 7: ...ost rainfall comes from the South West This is therefore the preferred side of the roof for the rain sensor but check local conditions especially on the East Coast or on Mainland Europe 15 TO 45 PITCH...

Page 8: ...kept free of grease and sealing compound OPENING ADJUSTMENT Within the opening distance selected at the actuator the opening distance when opening automatically can be adjusted in the range 100 300mm...

Reviews: