94
5. LIMIT SWITCHES
1. Take the blue wired limit switch from the bottom left corner and connect it to x-end stop. Fig. 264.
2. Take the red wired limit switch from the bottom left corner and connect it to y-end stop. Fig. 265.
3. Take the black wired limit switch from the bottom right corner and connect it to z-end stop. Fig. 266.
Run the black wired limit switch under the main board before connecting it. This ensures better cable
management.
4. Use the Velcro part to keep all the limit switch wires together.
6. FAN
1. Take the red-black wired fan cable and run it under the main board.
2. Connect the fan to Fan pwm. Fig. 267.
265
264
266
267