40
Open Ramp Up
Adjusts the Ramp Up distance before maximum running speed is reached when the gate is opening.
Opening Speed
Adjusts the maximum opening speed.
Open Ramp Down
Adjusts the Ramp Down distance before running at crawl speed when the gate is opening.
It should be noted that a very short ramp down may damage plastic rack or place unnecessary strain
on the gate motor, especially if the gate is heavy.
Open Crawl Speed
Adjusts the opening crawl speed. This speed should be high enough that the gate does not stall while
opening but slow enough that the gate does not stop abruptly when reaching the fully open position.
Open Crawl Distance
Adjusts the Crawl Distance when in the opening mode.
Open Gap Size
Adjusts the space between the gate and the physical ‘open end stop’ when the gate is in the fully
open posi2on.
It should be noted that if the gate is set up to use Posi2ve Close this se?ng is ignored.
Close Ramp Up
Adjusts the Ramp Up distance before maximum running speed is reached when the gate is closing.
Closing Speed
Adjusts the maximum closing speed. Useful for sites with high pedestrian traffic to reduce the speed.
Close Ramp Down
Adjusts the Ramp Down distance before running at crawl speed when the gate is closing.
See note with Open Ramp Down!
Close Crawl Speed
Adjusts the closing crawl speed. This speed should be high enough that the gate does not stall while
closing but slow enough that the gate does not stop abruptly when reaching the fully closed position.
Close Crawl Distance
Adjusts the Crawl Distance when in the closing mode.
Close Gap Size
Adjusts the space between the gate and the physical ‘close end stop’ when the gate is in the fully
closed posi2on.
See note with Open Gap Size!
Trigger Stop Distance
Determines how abruptly the operator will stop if it receives a trigger while the gate is moving by
adjus2ng the final travel distance aLer receiving a trigger.
A fast, heavy gate can damage plas2c rack if it stops too abruptly.
IR Stop Distance
Determines how abruptly the operator will stop if the safety beams are broken while the gate is
moving by adjus2ng the final travel distance aLer receiving signal from the safety beams.
See note with Trigger Stop Distance!
Dynamic Adjust
Enables or disables Dynamic Adjust (See Dynamic adjust under Gate Setup, Safety Se?ngs).
Pre Open Delay
Sets the delay from the 2me the controller receives a trigger to the 2me the operator opens the
gate. Typical use is to allow for a warning signal before opening the gate. The controller light output
can be set to flash during this period.
Pre Close Delay
Sets the delay from the 2me the controller receives a trigger to the 2me the operator closes the gate.
Typical use is to allow for a warning signal before closing the gate. The controller light output can be
set to flash during this period.
Con2nues……...