Two op2ons for power supply:
1. Op2on 1 (Recommended):
Low voltage supply 14-24V AC via transformer placed in the house, max 50m from operator with 3 core
1.5mm
2
(Live, Neutral & Earth).
2. Op2on 2:
High voltage mains supply connected to a 220V/240V AC Double Pole Isolator switch, mounted within 1.5m of
the operator connected to the transformer inside the operator. Isolator may not be obscured by the gate
when in open posi2on. Op2on 2 should be carried out by a qualified electrician.
3. Intercom gate sta2on to operator (consult with Intercom supplier for cable requirements)
4. Keypad to operator (consult with keypad supplier for cable requirements)
5. CLOSING Infrared beams to operator. Highly recommended for safe opera2on (4 core 0.5mm
2
mul2-stranded
cable)
6. OPENING Infrared beams to operator. Highly recommended for safe opera2on (4 core 0.5mm
2
mul2-stranded
cable)
7. Exit Loop to operator (1 core- consult with loop detector supplier for cable requirements)
CABLE RECOMMENDATIONS
3
1
2
4
7
5
6
•
ALL CABLES SHOULD BE PLACED IN CONDUIT
•
THERE SHOULD BE NO CABLE JOINTS INSIDE THE
CONDUIT