Mode No. Setting of analog input scaling data (A2-type)
P-09
A B C D E F
P - 0 9
G H I J K L ※A decimal point can be set up to the 3rd place.
1 0 0 0. It sets to a decimal point by a Shift key,
and moves a decimal point by a rise key.
deceleration flow value
0. 000~9999.
1.
The indicated value in the analog MAX
0.001~9999
(Do not set 0000)
Setting the indicated value in the analog MAX. Please set up for a 4-figure
numerical value.
It can set up to "0.001~9999" by moving a decimal point.
<Caution>
The indicated value in the analog input MIN is being fixed to "0."
Mode No.
Setting of deviation error (analog input : setting of output of upper and lower
limit・decision prohibit time・use of decision prohibit time ) (A2-type)
P-10
A B C D E F
P - 1 0
G H I J K L
1 6 0
Use of decision Prohibit time
0‥‥It is not used.
1‥‥It is used.
Decision prohibit time
0‥‥100 sec 5‥‥50 sec
1‥‥10 sec 6‥‥60 sec
2‥‥20 sec 7‥‥70 sec
3‥‥30 sec 8‥‥80 sec
4‥‥40 sec 9‥‥90 sec
Setting of output of Upper and lower limit
0‥‥output of Upper and lower limit
1‥‥output of Upper limit
2‥‥output of Lower limit
<Caution>about a decision prohibit time
After power activation or after reset ON/OFF、It is not outputted within decision
prohibition time.