SARA-R4/N4 series - AT Commands Manual
UBX-17003787 - R09
18 Internet protocol transport layer
Page 198 of 307
18.18.2 Syntax
Type
Syntax
Response
Example
Set
AT+UDCONF=3,<socket_id>,
<sending_timer_timeout>
OK
AT+UDCONF=3,1,1000
OK
Read
AT+UDCONF=3,<socket_id>
+UDCONF: 3,<socket_id>,<sending_
timer_timeout>
OK
AT+UDCONF=3,1
+UDCONF: 3,1,1000
OK
18.18.3 Defined values
Parameter
Type
Description
<socket_id>
Number
Socket identifier; used when changing the UDP Direct Link settings.
Allowed range is 0-6
<sending_timer_
timeout>
Number
Sending timer (in milliseconds) for UDP direct link; valid range is 100-120000; the
default value is 1000 ms
18.19 Timer Trigger configuration for Direct Link +UDCONF=5
+UDCONF=5
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M
Modules
SARA-N4
Syntax
PIN required
Settings saved Can be aborted
Response time Error reference
Attributes
full
No
No
No
-
18.19.1 Description
Sets the timer trigger of the interested socket identifier for the data transmission enhanced Direct Link.
18.19.2 Syntax
Type
Syntax
Response
Example
Set
AT+UDCONF=5,<socket_id>,
<timer_trigger>
OK
AT+UDCONF=5,0,500
OK
Read
AT+UDCONF=5,<socket_id>
+UDCONF: 5,<socket_id>,<timer_
trigger>
OK
AT+UDCONF=5,0
+UDCONF: 5,0,500
OK
18.19.3 Defined values
Parameter
Type
Description
<socket_id>
Number
Socket identifier; used when changing the UDP Direct Link settings.
Valid range is 0-6
<timer_trigger>
Number
Enhanced Direct Link sending timer trigger (in milliseconds); valid range is 0, 100 120
000; the factory-programmed value is 500 ms for UDP, 0 for TCP, 0 means trigger
disabled