SARA-G450 - System integration manual
UBX-18046432 - R08
System description
Page 31 of 143
C1-Public
describes the 8N1 frame format, which is the default configuration.
D0
D1
D2
D3
D4
D5
D6
D7
Start of 1-Byte
transfer
Start Bit
(Always 0)
Possible Start of
next transfer
Stop Bit
(Always 1)
t
bit
= 1/(Baudrate)
Normal Transfer, 8N1
Figure 14: Description of UART default frame format (8N1) with fixed baud rate
1.9.1.2
UART AT interface configuration
The UART interface of SARA-G450 modules is available as an AT command interface with the default
configuration described in
(for more details and information about further settings, see the
Interface
AT Settings
Comments
UART interface AT interface: enabled
AT command mode is enabled by default on the UART physical interface
AT+IPR=0
One-shot automatic baud-rate detection enabled by default
AT+ICF=3
Frame format 8N1 enabled by default
AT&K3
HW flow control enabled by default
AT&S1
DSR line set ON in data mode
and set OFF in command mode
8
AT&D1
Upon an ON-to-OFF transition of DTR, the DCE enters online command mode
and issues an OK result code
AT&C1
Circuit 109 changes in accordance with the Carrier detect status; ON if the
Carrier is detected, OFF otherwise
MUX protocol: disabled
Multiplexing mode is disabled by default and it can be enabled by AT+CMUX
command.
Table 8: Default UART AT interface configuration
1.9.1.3
UART signal behavior
At the module switch-on, before the UART interface initialization (as described in the power-on
sequence detailed in
), each pin is first tri-stated and then is set to its related internal reset
state
9
. At the end of the boot sequence, the UART interface is initialized, the module is by default in
active mode, and the UART interface is enabled as AT commands interface.
The configuration and the behavior of the UART signals after the boot sequence are described below.
for definition and description of module operating modes referred to in this section.
RXD signal behavior
The module data output line (RXD) is set by default to the OFF state (high level) at UART initialization.
The module holds RXD in the OFF state until the module does not transmit some data.
8
See the u-blox AT Commands Manual
for the definition of command mode, data mode, and online command mode.
9
See the pin description table in the SARA-G450 data sheet