7. Set up the operating parameters—Activate the pushbutton

 

SP/XX/IG/12/E/980228

7-3

  Pushbutton models

  Pushbutton deactivation

By default, the pushbutton on ScanPlus pushbutton models is deactivated.

Pushbutton Not Active (*)

  Pushbutton activation

  Pushbutton operating scenario

Other pushbutton operating scenarios are provided in the 

ScanPlus Reference Manual.

The same operating scenario is provided for all pushbutton models—
when the pushbutton is pressed, the ScanPlus remains active for a
default period of 2 s and goes into standby before the end of this period
if there is a good read.

standby

2 s

good read

press pushbutton

Active For Read Duration (2 s)—Standby After Good Read

Summary of Contents for ScanPlus 1800

Page 1: ...SP XX IG 12 E 980228 S c a n P l u s Installation Guide Edition 1 2...

Page 2: ...onal purposes only and is subject to change without notice No part of this manual may be copied or reproduced in any manner without the prior written permission of United Barcode Industries ScanPlus p...

Page 3: ...1 1 1992 EN 55022 1987 Class B Immunity EN 50082 1 1992 IEC 801 2 1984 91 8kV in the air IEC 801 3 1984 3 V m IEC 801 4 1988 1kV Low voltage EN 60950 1993 following the provisions of Directives 89 336...

Page 4: ...iv SP XX IG 12 E 980228...

Page 5: ...to install and set up your ScanPlus 1 Check you have everything you need 1 1 2 Switch off the host system and connect up the ScanPlus 2 1 3 Switch on the host system 3 1 4 Enter the interface number f...

Page 6: ...What you are going to do vi SP XX IG 12 E 980228...

Page 7: ...t provide enough electrical power to drive the ScanPlus keyboard wedge ScanPlus connected between a keyboard and the host system data from the ScanPlus is transmitted in keyboard emulation mode to pro...

Page 8: ...1 Check you have everything you need SP XX IG 12 E 980228 1 2...

Page 9: ...o the host system or you will need to use a CMM cable adapter Host interfaces Keyboard wedge ScanPlus with Y cable PC AT and compatible 2 2 Keyboard wedge CMM and external power supply if required 2 3...

Page 10: ...been designed to fit tightly in the Y cable socket tilt the jack slightly to ease insertion 1 and then push hard vertically 2 0 0Do not switch on the host computer until you have connected up and plu...

Page 11: ...cable CMM to host cable keyboard to CMM cable wedge CMM Reader Power Supply To Display To Keyboard power supply optional to keyboard input connector 0 0Do not switch on the host computer until you hav...

Page 12: ...output CMM and external power supply single RS 232 CMM Reader Power Supply RS 232 Port power supply serial port 0 0Do not switch on the host computer until you have connected up and plugged in the ex...

Page 13: ...nd the host computer reverse gender dual output RS 232 CMM 0 0Do not switch on the host computer until you have connected up and plugged in the external power supply By default dual output RS 232 CMMs...

Page 14: ...Plus SP XX IG 12 E 980228 2 6 IBM 46xx cash registers port 5x or 9x 1 Switch off the host system 2 Connect the ScanPlus to the cash register OCIA cash registers scanner input port 1 Switch off the hos...

Page 15: ...ScanPlus SP XX IG 12 E 980228 2 7 Laser emulation scanner input port 1 Switch off the host system 2 Connect the ScanPlus to the host computer Wand emulation scanner input port 1 Switch off the host sy...

Page 16: ...2 Switch off the host system and connect up the ScanPlus SP XX IG 12 E 980228 2 8...

Page 17: ...y default setting all models no LED laser emulation x x x x x x 0 x x x x 1 flash wand emulation x x x x x x 1 x x x x 2 flashes RS 232 C x x x x x x 2 x x x x 3 flashes IBM 46xx cash registers x x x...

Page 18: ...3 Switch on the host system SP XX IG 12 E 980228 3 2...

Page 19: ...ded in this Installation Guide The ScanPlus has special beeps for configuration bar codes two beeps indicate that the ScanPlus has successfully read the configuration code and saved the setting six sh...

Page 20: ...you do not find an interface number for your host system configuration If your interface number is not among the predefined interface numbers provided below you must compose the number yourself If yo...

Page 21: ...12 E 980228 3 4 3 Keyboard wedge IBM PC AT and compatible N 200 QWERTY English N 201 AZERTY French N 204 QWERTZ German N 205 QWERTY Swedish Finnish N 206 QWERTY Italian N 207 QWERTY Norwegian N 208 QW...

Page 22: ...SP XX IG 12 E 980228 4 4 Keyboard wedge IBM 31xx 32xx 34xx N 230 QWERTY English N 231 AZERTY French N 232 AZERTY international N 233 AZERTY caps QWERTY N 234 QWERTZ German N 2310 QWERTY data entry N 2...

Page 23: ...DEC VT 220 320 420 N 410 QWERTY PC type N 411 AZERTY PC type N 414 QWERTZ PC type N 415 QWERTY PC type Swedish Finnish DEC VT PC 510 N 271 AZERTY PC type N 275 QWERTY PC type Swedish Finnish N 2717 AZ...

Page 24: ...edge Apple Macintosh N 220 QWERTY English N 221 AZERTY French N 224 QWERTZ German Hewlett Packard 700 92 N 260 QWERTY English N 261 AZERTY French N 264 QWERTZ German Wyse 60 65 99GT 120 N 300 QWERTY 1...

Page 25: ...face number for your host system SP XX IG 12 E 980228 7 4 7 RS 232 N 100 Standard RS 232 C 9600 7 E 2 N 101 RS 232 TTL Level N 102 RS 232 PC Term N 103 RS 232 Compatible ScanPlus CL Slave Mode N 105 R...

Page 26: ...Emulation Intermec Interface Read N 131 Analog Wand Emulation Intermec Interface if you want to use the following ScanPlus products ScanPlus SP P N 0 320311 11 ScanPlus ER P N 0 330311 11 ScanPlus XP...

Page 27: ...IG 12 E 980228 9 4 9 IBM 46xx cash registers N 110 IBM 46xx cash registers Port 9x N 111 IBM 46xx cash registers Port 5x OCIA cash registers N 120 OCIA TEC cash registers First Type N 121 OCIA TEC ca...

Page 28: ...4 Enter the interface number for your host system SP XX IG 12 E 980228 4 10...

Page 29: ...se your ScanPlus to read the configuration codes if required The full set of data transmission parameter options for all the host system interfaces supported is provided in the ScanPlus Reference Manu...

Page 30: ...G 12 E 980228 5 2 Keyboard wedge An asterisk indicates the predefined parameter settings for keyboard wedge interface N 200 QWERTY English Inter character delay No Delay 20 ms Postamble Enter Carriage...

Page 31: ...iers not transmitted transmitted special keys interpretation Code 39 not active always active only active if separate 2 character label or if preceded by a hyphen only active if separate 2 character l...

Page 32: ...ssion parameters SP XX IG 12 E 980228 5 4 RS 232 An asterisk indicates the predefined parameter settings for interface N 100 Standard RS 232 C Baud Rate 9600 19200 Data bits Seven Eight Parity Even Od...

Page 33: ...ta transmission parameters SP XX IG 12 E 980228 5 5 RS 232 RTS CTS hardware protocol Not Active Active Inter character delay No Delay 10 ms Postamble Carriage Return Line Feed Carriage Return Line Fee...

Page 34: ...06 not used ACK HEX 06 user defined NAK Hex 15 not used NAK HEX 15 user defined XON XOFF software protocol not active active LRC longitudinal redundancy check not active active preamble no preamble us...

Page 35: ...signal state outside transmission quiet zone 1 quiet zone 0 Wand emulation Additional parameters ScanPlus Reference Manual An asterisk indicates the predefined parameter settings for interface N 130 d...

Page 36: ...ing for interface N 110 N 111 IBM 46xx cash registers Port 9x Port 5x inter message delay none 1 to 999 ms OCIA cash registers Additional parameters ScanPlus Reference Manual The main predefined param...

Page 37: ...Plus model certain symbologies are already selected by default ScanPlus SP ER XP Code 39 UPC EAN code families ScanPlus PDF PDF417 This section provides the different symbology activation codes and so...

Page 38: ...can the Reset Factory Defaults bar code provided in Appendix C but you will then have to completely reconfigure your ScanPlus In most cases it is easier to perform the following symbology reset proced...

Page 39: ...ree scanning do not select symbologies that you do not need deactivate the Code 39 and UPC EAN default symbologies if you do not need to use them Keep a list of your custom settings this will be usefu...

Page 40: ...that you use one of the following parameters with all ScanPlus products Compose 1 or 2 Fixed Lengths the safest configuration Compose Minimum Length Compose 1 or 2 Fixed Lengths provides the best secu...

Page 41: ...ngth End Selection second length End Selection End Selection Compose Minimum Length default 6 minimum length Compose Minimum Length length End Selection Additional parameters ScanPlus Reference Manual...

Page 42: ...is only available with the ScanPlus XP and ScanPlus PDF Select the desired Codablock format and scan Active to enable Not Active Active Codablock F Codablock A Check digit Not Transmitted Transmitted...

Page 43: ...bology parameters SP XX IG 12 E 980228 6 7 Code 39 Activation Active ScanPlus SP ER XP Not Active ScanPlus PDF Standard 43 Characters Full ASCII Start stop Not Transmitted Transmitted Check digit Chec...

Page 44: ...d Barcode length The minimum length possible for Code 39 is 3 characters start barcode data check digit if applicable stop Compose Minimum Length is recommended if you know the minimum length of the c...

Page 45: ...rs only only and accepted modulo 43 check digit checked and transmitted checked but not transmitted barcode length number of characters any length minimum length 6 special keys interpretation keyboard...

Page 46: ...logy parameters SP XX IG 12 E 980228 6 10 Code 93 Activation Not Active Active Additional parameters ScanPlus Reference Manual barcode length number of characters any length minimum length 6 minimum l...

Page 47: ...with Code 128 recognition of the FNC1 start character used Activation Not Active Active EAN 128 identifier The C1 AIM identifier for EAN 128 is automatically added by default in front of EAN 128 bar...

Page 48: ...0228 6 12 Code 128 EAN 128 Additional parameters ScanPlus Reference Manual FNC1 separator character EAN 128 norms GS function character ASCII 29 user defined barcode length number of characters any le...

Page 49: ...ted as 5 narrow bars In this case all useful characters are transmitted For maximum security we strongly recommend that you use one of the following parameters with all ScanPlus products Compose 1 or...

Page 50: ...s first length End Selection second length End Selection End Selection Compose Minimum Length default 6 minimum length Compose Minimum Length length End Selection Additional parameters ScanPlus Refere...

Page 51: ...curity we recommend that you use the Compose Minimum Length parameter with all ScanPlus products Use the special number codes provided on the back cover of this Installation Guide and scan End Selecti...

Page 52: ...Mod 10 Checked And Transmitted Check Digit Mod 10 Checked But Not Transmitted Check Digit Double Mod 10 Checked And Transmitted Check Digit Double Mod 10 Checked But Not Transmitted Additional paramet...

Page 53: ...6 Set up the symbology parameters SP XX IG 12 E 980228 6 17 PDF417 Activation PDF417 is only available with the ScanPlus PDF Not Active Active...

Page 54: ...G 12 E 980228 6 18 Plessey Code Activation Not Active Active Check digit Not Transmitted Transmitted Additional parameters ScanPlus Reference Manual barcode length number of characters any length mini...

Page 55: ...r maximum security we strongly recommend that you use one of the following parameters with all ScanPlus products Compose 1 or 2 Fixed Lengths the safest configuration Compose Minimum Length Compose 1...

Page 56: ...2 Fixed Lengths first length End Selection second length End Selection End Selection Compose Minimum Length default 6 minimum length Compose Minimum Length length End Selection Additional parameters...

Page 57: ...EAN 13 Activation Active UPC EAN ScanPlus SP ER XP Not Active UPC EAN ScanPlus PDF UPC A Transmitted as EAN 13 UPC A Transmitted as UPC A Add On Digits Not Required But Transmitted If Read Add On Digi...

Page 58: ...EAN code format leading character number system data check digit UPC A Check Digit Transmitted UPC A Check Digit Not Transmitted UPC E Check Digit Transmitted UPC E Check Digit Not Transmitted EAN 8 C...

Page 59: ...ntry code select the parameter UPC A Transmitted As EAN 13 UPC A Number System Transmitted UPC A Number System Not Transmitted UPC E Number System Transmitted UPC E Number System Not Transmitted Addit...

Page 60: ...6 Set up the symbology parameters SP XX IG 12 E 980228 6 24...

Page 61: ...hbutton model you may still have to activate the pushbutton the pushbutton is deactivated by default Use your ScanPlus to read the appropriate pushbutton activation code provided on the following page...

Page 62: ...he reading light and read function are switched off Full energy is restored when the next reading situation occurs ScanPlus ER XP PDF standard pushbutton models can be configured to produce an aiming...

Page 63: ...on Pushbutton operating scenario Other pushbutton operating scenarios are provided in the ScanPlus Reference Manual The same operating scenario is provided for all pushbutton models when the pushbutto...

Page 64: ...ood Read Activation Standard pushbutton models Aiming beam Only supported by ScanPlus ER XP PDF models with part numbers 0 xxxxxx 2x xx 0 0Do not use this code with ScanPlus models that do not have a...

Page 65: ...read active while pushbutton pressed standby after good read standard pushbutton models aiming beam active for read duration 2 s repeat read duration after good read active while pushbutton pressed st...

Page 66: ...rary configuration mode enable restore current configuration update current configuration transparent configuration mode enable display data string mode enable RS 232 slave mode enable Flashing mode L...

Page 67: ...onsecutive same read data validation single read before transmission user defined number of consecutive same reads before transmission maximum 10 time out between identical consecutive codes 300 ms us...

Page 68: ...7 Set up the operating parameters Activate the pushbutton SP XX IG 12 E 980228 7 8...

Page 69: ...lear to Send 5 Clear to Send 6 NC 6 NC 7 Signal Ground 7 Signal Ground 8 NC 8 NC 12 5 Volts 12 5 Volts 20 NC 20 NC Standard DB 25S DCE female P N 704320 Standard AT 9 pin serial DCE female P N 704340...

Page 70: ...A Pin assignments Single output RS 232 CMM SP XX IG 12 E 980228 A 2...

Page 71: ...he cover of the CMM 2 Set the jumpers as required see the available settings on the next page Jumper settings are identical for standard and reverse gender dual output RS 232 CMMs Make sure the TO HOS...

Page 72: ...C1 IC2 IC3 IC4 IC1 J3 J4 X1 X2 X3 C12 J1 J2 2 RXD 3 TXD 4 CTS 5 RTS 7 GND 9 5V TXD 2 RXD 3 RTS 4 CTS 5 GND 7 5V 9 C16 C5 C10 Jumper settings Data transmission settings transmit to host and terminal t...

Page 73: ...llowing checklists if you have any of the following problems no LEDs no beeps error beeps no transmission incorrect transmission Setup problems checklist correct ScanPlus model correct CMM cables exte...

Page 74: ...odes fragile symbologies read the appropriate test code to see if there is a problem with the symbology Appendix D correct operating parameters pushbutton activated pushbutton pressed aiming beam acti...

Page 75: ...0 If you scan Reset Factory Defaults you will have to re enter the appropriate interface number for your host system and any custom settings if applicable It is often easier to reset individual param...

Page 76: ...f required section 6 Set up the symbology parameters 7 If you have a pushbutton model activate the pushbutton section 7 Set up the operating parameters Activate the pushbutton If you still have a prob...

Page 77: ...SP XX IG 12 E 980228 D 1 DTest codes Codabar 123456 Code 39 CODE 39 Code 93 CODE 93 Code 128 CODE 128 EAN 128 C1EAN 128 Interleaved 2 of 5 12345678901234 Standard 2 of 5 123456 Matrix 2 of 5 012345...

Page 78: ...ode 12345666 Plessey Code 80001495050 EAN 8 12345670 EAN 13 1234567890128 UPC A 0 0 1 2 3 4 5 0 0 0 0 7 UPC E 0 0 1 2 3 4 5 7 Codablock F UBI ScanPlus XP and XP PDF CCD Bar Code Scanners PDF417 UBI Sc...

Page 79: ...i Savena Bologna ITALY Tel 39 51 453270 Fax 39 51 450460 UBI GmbH Max Planck Strasse 9 13 D 85716 Unterschleissheim M nchen GERMANY Tel 49 89 32 18 10 0 Fax 49 89 32 18 10 20 UBI Nordic AB Bredgatan 1...

Page 80: ...SP XX IG 12 E 980228 UBI Part Number 0 300049 01 12 Number codes 1 2 3 4 5 6 7 8 9 0 End Selection...

Reviews: