6. Set up the symbology parameters
SP/XX/IG/12/E/980228
6-2
Symbology default settings
When you install your ScanPlus for the first time, Code 39 and UPC/EAN (ScanPlus SP /
ER / XP) or PDF417 (ScanPlus PDF) are preselected by default and all the symbology
parameters are set to their factory default settings.
The symbology default settings are global factory defaults—they are independent of the
different symbology activation codes.
Factory default settings are indicated by an asterisk (*).
Resetting symbology default settings
If you want to reset all the default symbology settings, you can scan the Reset Factory
Defaults bar code provided in Appendix C, but you will then have to completely reconfigure
your ScanPlus.
In most cases, it is easier to perform the following symbology reset procedure.
1.
Scan the Disable All Symbologies bar code:
Disable All Symbologies
2.
Select the activation codes for the symbologies you want to read.
3.
Customize the symbology parameter settings if required.
The Disable All Symbologies code deactivates all the symbologies activated. If you want to
deactivate individual symbologies, use the Not Active codes for each symbology.
Disable All Symbologies does not reset the individual parameter settings for each
symbology. When you reactivate a symbology, you recover the parameter settings stored
in memory for that symbology when it was disabled.
Summary of Contents for ScanPlus 1800
Page 1: ...SP XX IG 12 E 980228 S c a n P l u s Installation Guide Edition 1 2...
Page 4: ...iv SP XX IG 12 E 980228...
Page 6: ...What you are going to do vi SP XX IG 12 E 980228...
Page 8: ...1 Check you have everything you need SP XX IG 12 E 980228 1 2...
Page 16: ...2 Switch off the host system and connect up the ScanPlus SP XX IG 12 E 980228 2 8...
Page 18: ...3 Switch on the host system SP XX IG 12 E 980228 3 2...
Page 28: ...4 Enter the interface number for your host system SP XX IG 12 E 980228 4 10...
Page 60: ...6 Set up the symbology parameters SP XX IG 12 E 980228 6 24...
Page 68: ...7 Set up the operating parameters Activate the pushbutton SP XX IG 12 E 980228 7 8...
Page 70: ...A Pin assignments Single output RS 232 CMM SP XX IG 12 E 980228 A 2...