5. Set up the data transmission parameters
SP/XX/IG/12/E/980228
5-6
RS-232
Additional parameters—ScanPlus Reference Manual
baud rate - 75 - 150 - 300 - 600 - 1200 - 2400 - 4800 -
38400
hardware/software protocols timeout - 1000 ms (*)
- unlimited
- user-defined 1 to 2500 ms
ENQ (Hex 05) - not used (*)
- ENQ (HEX 05)
- user-defined
ACK (Hex 06) - not used (*)
- ACK (HEX 06)
- user-defined
NAK (Hex 15) - not used (*)
- NAK (HEX 15)
- user-defined
XON/XOFF software protocol - not active (*)
- active
LRC (longitudinal redundancy check) - not active (*)
- active
preamble - no preamble
- user-defined
postamble - user-defined
"code mark" symbology identifiers - not transmitted (*)
- transmitted
- default / user-defined
AIM symbology identifiers - not transmitted (*)
transmitted
inter-character delay - 20 - 30 - 40 - 50 ms
- user-defined 1 to 999 ms
inter-message delay - none (*)
- 10 - 30 - 50 - 80 - 100 ms
- user-defined 1 to 999 ms
Summary of Contents for ScanPlus 1800
Page 1: ...SP XX IG 12 E 980228 S c a n P l u s Installation Guide Edition 1 2...
Page 4: ...iv SP XX IG 12 E 980228...
Page 6: ...What you are going to do vi SP XX IG 12 E 980228...
Page 8: ...1 Check you have everything you need SP XX IG 12 E 980228 1 2...
Page 16: ...2 Switch off the host system and connect up the ScanPlus SP XX IG 12 E 980228 2 8...
Page 18: ...3 Switch on the host system SP XX IG 12 E 980228 3 2...
Page 28: ...4 Enter the interface number for your host system SP XX IG 12 E 980228 4 10...
Page 60: ...6 Set up the symbology parameters SP XX IG 12 E 980228 6 24...
Page 68: ...7 Set up the operating parameters Activate the pushbutton SP XX IG 12 E 980228 7 8...
Page 70: ...A Pin assignments Single output RS 232 CMM SP XX IG 12 E 980228 A 2...