LISA-C2 series and FW75-C200 - System Integration Manual
UBX-13000620 - R21
Early Production Information
Design-In
Page 64 of 103
Application
Category
Immunity Level
All exposed surfaces of the radio equipment and ancillary equipment in
a representative configuration
Contact Discharge
4 kV
Air Discharge
8 kV
Table 32: Electromagnetic Compatibility (EMC) ESD immunity requirement, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN
301 489-7 V1.3.1”
Although EMC certification (including ESD immunity testing) must be performed in the final application of the
radio equipment EUT, results are provided for LISA modules performing the test with a representative
configuration to show that requirements can be met.
Since an external antenna is used, the antenna port can be separated from the enclosure port. The reference
application is not enclosed in a box so the enclosure port is not identified with physical surfaces. Therefore, some
test cases cannot be applied. Only the antenna port is identified as accessible for direct ESD exposure.
The reference application implements all precautions described in the sections below. ESD immunity test results
and applicability are reported in Table 33 according to test requirements [13], [14] and [15].
Category
Application
Immunity Level
Contact Discharge to coupling
planes (indirect contact discharge)
Enclosure
+2 kV / -2 kV
+4 kV / -4 kV
Contact Discharges to conducted
surfaces (direct contact discharge)
Enclosure port
Not Applicable
Contact Discharges to conducted
surfaces (direct contact discharge)
Antenna port
(only antenna with completely insulating surface can be used)
Not Applicable
Air Discharge at insulating surfaces
Enclosure port
Not Applicable
Air Discharge at insulating surfaces
Antenna port
(only antenna with completely insulating surface can be used)
+2 kV / -2 kV
+4 kV / -4 kV
+8 kV / -8 kV
Table 33: Enclosure ESD immunity level result, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1” for LISA
application reference design.
5
LISA mounted on application design:
Not Applicability -> EUT with insulating enclosure surface, EUT without enclosure surface
Applicability -> EUT with conductive enclosure surface
6
LISA mounted on application design:
Not Applicability -> Antenna with insulating surface
Applicability -> Antenna with conductive surface
7
LISA mounted on application design:
Applicability -> EUT with insulating enclosure surface
Not Applicability -> EUT with conductive enclosure surface, EUT without enclosure surface