REPLACING THE LIGHT BULBS
(see illustration below). For convenience, if a bulb
burns out, it is a good idea to replace all of the bulbs
at the same time.
1.) Turn the master power switch off, then UNPLUG
the power cord from the wall.
2.) If fireplace has been operating, let the unit cool at
least 2 hours.
3.) Loosen the 2 screws recessed in the front kick plate
(see illustration below). Gently pull the kick plate
towards you (careful not to scratch the fireplace
hearth/base).
4.) Unhook the light bulb spring clip from the bulbs
then unscrew the bulbs. After replacing the bulbs
make sure to replace the light bulb spring clip.
5.) Remove light bulbs and replace with (3) clear 120V,
40 Watt E12 Socket base light bulbs, (2) bulbs for
18E05 Insert, via pull-out tray.
6.) Slide kick plate back into position and tighten
recessed screws. (Careful not to over tighten).
WARNING: Do not exceed 40 Watts per
bulb. Use of higher rated bulbs may
result in a fire, causing property dam-
age or personal injury.
3. Remove Kickplate to Access Lightbulbs
4. Replace all Lightbulbs
1. Loosen reccessed
phillips head screw
2. Loosen reccessed
phillips head screw
M A I N T E N A N C E O F M O T O R S
The motors used on the fan and the flame generator
assembly are pre-lubricated for extended bearing life
and require no further lubrication. However, periodic
cleaning/vacuuming of the fan/heater unit is recom-
mended. The louvers/vent in the control door should
be cleaned periodically, both inside and out. When the
control door is in the open position the heater
grill/screen should be vacuumed. The area around the
controls should also be kept clean. Make sure the unit
is turned OFF and unplugged whenever you are clean-
ing the heater or fireplace.
WARNING: Make sure the power is
turned off before proceeding. Any elec-
trical repairs or rewiring of this unit
should be carried out by a licensed elec-
trician in accordance with national and
local codes.
If repairing or replacing any electrical component or
wiring, the original wire routing, color coding and
securing locations must be followed.
WARNING: Electrical outlet wiring
must comply with local building codes
and other applicable regulations to
reduce the risk of fire, electrical shock
and injury to persons.
WARNING: Do not use this fireplace if
any part of it has been under water.
Immediately call a qualified service tech-
nician to inspect the fireplace and replace
any part of the electrical system.
Warning: Disconnect power before
attempting any maintenance or clean-
ing to reduce the risk of fire, electrical
shock or personal injury.
E-5
LIGHT BULB HOLDING SPRING
This fireplace uses (3) clear 120V, 40 Watt E12 Socket
base light bulbs (open small base, chandelier candle
type). The 18E05 insert only requires (2) clear 120V,
40 Watt E12 Socket bulbs, installed in a pull-out tray
accessible once the kickplate has been removed. The 40
Watt bulbs are accessed through the front kick plate