Chapter 1 Introduction
- 5 -
θ is the include angle to the flow direction
M is the travel times of the ultrasonic beam
D is the pipe diameter
T up is the time for the beam from upstream transducer to the downstream one
T down is the time for the beam from downstream transducer to the upstream
one
ΔT=Tup –Tdown
1.5. Typical Application
Portable/handheld ultrasonic flowmeter is used to measure the flow and heat of
various single uniform liquids that can conduct ultrasonic waves.
Portable/handheld ultrasonic flowmeter adopts non-contact measurement method,
with large measurement range, no moving mechanical parts, and is not affected by
system pressure and harsh environment. It has been widely applied to water, pure
water, sea water, sewage, chemical liquids, rivers In the measurement of water,
fuel oil and other fluids. The upper limit temperature of the standard sensor is
110ºC. Please contact the manufacturer or supplier if the temperature exceeds this
temperature.
Portable/handheld ultrasonic energy meters are widely used in the measurement of
system energy consumption in refrigeration, heating, heat exchangers, freezers,
boilers and other industries.