ULTRAFEED VAF-4
Manual 0-5332
OPERATION 4-15
4.04 Wirefeeder Configuration for Different Power Sources
WARNING
There are dangerous voltage and power levels inside this product. Turn OFF Wirefeeder and disconnect
from the power source before removing cover from Wirefeeder.
The factory default setting for the Wirefeeder is set for the ArcMaster 401MST power source. If a different power
source is being used then the user will need to set the Display PCB DIP switch as to Table 4-6 according to the power
source being used.
Display PCB
Art # A-12469
DIP Switch
Figure 4-6 DIP Switch on Display PCB
S3S4S5
Vmin
Vmax
Vsetmin(J&L)
Vsetmax(J&L)
Welder
S3=Off(0), S4=On(1), S5=On(1)
10
36
2.3
8.17
ArcMaster 401MST (default)
ArcMaster 400MST
S3=Off(0), S4=Off(0), S5=Off(0)
14
50
3.182
11.364
Powermaster 550i
S3=On(1), S4=On(1), S5=Off(0)
14
40
3.182
9.091
Powermaster 350i
S3=On(1), S4=Off(0), S5=Off(0)
10
44
2.273
10
Transmig 500i
S3=On(1), S4=On(1), S5=On(1)
8
50
User Type Setting
Table 4-6 Voltage Setting
NOTE
When S6=ON(1), calibration functions in Advanced Features Mode is enabled; when S6=OFF(0), calibration
functions are disabled.
!
WARNING
Only when S1=OFF(0),S2=ON(1), WFS Setting is applicable for Ultrafeed VAF-4 and it ranges from 50 IPM
to 875 IPM.