OPERATION 4-1
SECTION 4: OPERATION
4.01 Front Panel Controls, Indicators and Features
Art # A-12467
Figure 4-1 Front Panel View
WARNING
DO NOT TOUCH the electrode wire while it is being fed through the system. The electrode wire will be at
welding voltage potential.
1. POWER Indicator
The red power indicator will be illuminated when the Wirefeeder is turned ON and indicates the presence of power.
2. FAULT Indicator
The yellow fault indicator will be illuminated when any faults are detected. Should a fault condition occur refer to Sec-
tions 4.24, 4.25, 5.01 or 5.02 for further information.
If the Fault indicator is flashing while welding refer to Section 4.25 as the motor overload protection is active.
3. AMPS Indicator
The red AMPS indicator will be illuminated when the Left Display displays the amperage.
4. IPM Indicator
The red IPM indicator will be illuminated when the Left Display displays WFS in Inches Per Minute (IPM).
5. MPM Indicator
The red MPM indicator will be illuminated when the Left Display displays WFS in Meters Per Minute (MPM).
6. Left Knob
The control knob adjusts Wire Feed Speed (WFS) (which in turn adjusts the output current by turning the amount of
MIG wire delivered to the welding arc). The optimum WFS required is dependent on the type of welding application.