4-14 OPERATION Manual 0-5332
Factory Default Setting
Advanced Feature
Left Display
Feature
Description
Right Display
(Default)
Comments
MIG Control
MIG/CNTR
LOCL
Pre Flow
PRE/FLOW
0.1
Run In
RUN/IN
70
Ramp Time
RAMP/TIME
0.2
Post Flow
POST/FLOW
0.1
Burn Back
BURN/BACK
0.15
Crater
CRAT
OFF
Only in 4T Mode
Crater Volts
CRAT/ VOLT
70
Only when in 4T Mode
and Crater is ON
Crater Wirefeed Speed
CRAT/ WFS
70
Only when in 4T Mode
and Crater is ON
Spot Time
SPOT/TIME
2.0
Only in Spot Mode
Stitch Mode
STCH
OFF
Only in 2T & 4T Modes
Stitch Time
STCH/TIME
2.0
Only when Stitch is ON
Dwell Time
DWEL/TIME
0.5
Only when Stitch is ON
Wirefeed Speed Units
WFS/UNIT
IPM
Left Display Type
LEFT/DISP
AMPS
Right Display Type
RGHT/DISP
VARC
Table 4-5 Factory Default Setting