Reset switch (CS-460 internal version)
A r eset switch is viewable beside the 5-pin m ini-DIN connector on the back-plate of the
card. It is a small micro-switch, and allows the user to restore the unit to Factory
Settings. This may be n ecessary if moving the card from one PC to another (eg. if the
RS232 baud rate is different, and you want to reset it to the default of 9600 baud).
Side view
of switch
Reset switch activation.
Performing a Factory Reset
1. Close down & turn off your computer.
2. Locate the micro-switch as shown in the diagram above.
3. Using a very small screwdriver, gently hold down the lever in the direction
shown in the diagram above. Note that the micro-switches hinge is nearest to
you.
4. Power-up the computer.
5. Release the micro-switch's lever about 1 second after turning on the computer.
Factory reset only occurs if the micro-switch is activated while the computer is being
turned on - it will not occur at any other time.
(Pressing the micro-switch emulates the depression of both the + and - buttons on the
external version of the Eclipse.)
NTSC selection
When doing a Factory Reset, you also chan ge the un it to work in NTSC. If you require it
to operate in PAL, you will need to use the RS232 Control method to select NTSC mode,
and then do a 'Store Settings' so that it is used in the future.
Alterna tively, i f you ha ve the Infra-Red Receiver Module, you can select PAL from the
Advanced menu using the on-screen display.