ACM 400 S motor control unit
18 / 24
You can now operate the gate system, either...
via the
external control station
, as connected in chapter 6)
or via die
membrane keyboard
(optional) [X5.5]..[X5.7]
In this case the gate moves...
open
when you press
[X5.5]
closed
when you press the Key
[X5.7].
The "Stop" key [X5.6] on the membrane keyboard has the same function, as Stop as
external control station.
LED "A" on the front membrane
[X5.2]
Gate status
Continuously on
limit position "Open"
Continuously off
limit position "Closed"
Flashes slowly (0.5Hz)
gate stopped along the path
Flashes quickly (4Hz)
Opening or closing
Before each motor start the warning light indicates the motor will be starting soon as
an advance warning. Both the time and running direction for this can be set (Menu
"6", page
Fehler! Textmarke nicht definiert.
).
c) Emergency operation
In order to enable controlled movement of the gate when safety equipment (closing
edge safety device, photoelectric barrier) is continuously actuated (e.g. in case of a
defect in a safety device)
keep one of the external "Open" / "Closed" buttons pressed for longer than 15s,
until the warning light goes on.
When you release the button the named waiting times are reset and the gate’s
movement is interrupted. Simply repeat these steps for another 2s movement.
Note:
It must be an external button or a membrane keyboard key.
Emergency operation is not possible via radio!
d) Read out trip counter
The "H" menu is a pure display menu
– it shows the number of "Open" movements of
the gate system to date.
-hand display
segment, the corresponding value of the position is displayed in the right-hand
display segment
Example: The consecutive display of the numbers 00 14 25 33 48 52 6- 7- therefore
means 045382-- movements, this is the number displayed one after the other in the
right-hand display segment.