24
NOTE
Oil levels should be checked every 24 hours of operation.
Proper oil drain schedules require oil be changed before the contaminant load becomes so great that the
lubricating function of the oil is impaired or heavy disposition of suspended contaminants occurs. To check
the condition of the oil, drain a sampling into a clean container and check for the presence of water or solids.
Slight discoloration of the oil should not necessitate an oil change.
7.3 SPARE PARTS
Should adjustments or replacement eventually be needed, these can often be performed locally as
described in this book after obtaining required parts. Personnel should have a good background of
mechanical experience and be thoroughly familiar with the procedures outlined in this manual. Major
repairs not covered in this book should be referred to the nearest Tuthill Vacuum & Blower Systems service
representative.
When ordering parts, give all booster nameplate information, as well as the item number and parts description
as per the parts lists and assembly drawings for your particular model. Repair kits are available for all
models. These kits contain all of the seals, bearings, O-rings, locks, and special retaining screws necessary
for an overhaul. For your convenience when ordering parts, we suggest you complete the
Operating Data
Form
included on the inside, back cover of this manual.
In developing a stock of spare parts, consider the following:
• The degree of importance in maintaining the booster in a “ready” condition
• The time lag in parts procurement
• Cost
• Shelf life (seals and O-rings)
Contact Tuthill Vacuum & Blower Systems Service Department for any assistance in selecting spare parts.
Telephone: (417) 865-8715 — Toll Free (48 contiguous states): (800) 825-6937 — Fax: (417) 865-2950
7.4 FACTORY SERVICE & REPAIR
With proper care, Tuthill Vacuum & Blower Systems boosters will give years of reliable service. The parts
are machined to very close tolerances and require special tools by mechanics who are skilled at this work.
Should major repairs become necessary, contact the factory for the authorized service location nearest you.
Units which are still under warranty must be returned to the factory, freight prepaid, for service.
Tuthill Vacuum & Blower Systems
ATTN: Inside Service Manager
4840 West Kearney Street
Springfield, MO 65803-8702
NOTE
Current regulations require Material Safety Data Sheet to be completed and
forwarded to Tuthill Corporation on any unit being returned for any reason
which has been handling or involved with hazardous gases or materials.
This is for the protection of the employees of Tuthill Corporation who are
required to perform service on this equipment. Failure to do so will result
in service delays.
NOTE
When returning a booster to the factory for repair, under warranty, please
note the factory will not accept any unit that arrives without authorization.
Contact the Service Department for return authorization.
Summary of Contents for M-D Pneumatics 7010
Page 43: ...43 NOTES ...
Page 50: ...50 3200C CUTAWAY DRAWING 3200 90C 91C 92C 93C 1 OF 2 A ...
Page 51: ...51 3200C CONFIGURATIONS DRAWINGS 3200 90C 91C 92C 93C 2 of 2 A ...
Page 54: ...54 5500C CUTAWAY DRAWING 5500 90C 91C 92C 93C 1 OF 2 E OIL LEVEL SIGHT GAUGE DETAIL ...
Page 55: ...55 5500C CONFIGURATIONS DRAWINGS 5500 90C 91C 92C 93C 2 of 2 E ...
Page 56: ...56 7000C CUTAWAY DRAWING 7000 90C 91C 1 OF 3 ...
Page 57: ...57 7000C CONFIGURATIONS DRAWING 7000 90C 2 OF 3 ...
Page 58: ...58 7000C CONFIGURATIONS DRAWING 7000 91C 3 OF 3 7000 91C 7013 SHOWN ...
Page 68: ...68 NOTES ...