WARNING
Physical harm may occur if human body parts are in contact or exposed to
the process vacuum. Assure that all connections are protected from human
contact.
WARNING
If rated vacuum or pressure levels are exceeded, process fluids will migrate
to other parts of the booster and system.
CAUTION
Do not touch hot surfaces.
The upper limit of the booster operation is 375º F (190º C). Do not touch
the booster while it is in operation and assure booster is cool when not in
operation.
CAUTION
Use of a thermowell insulates the thermocouple. Invalid and delayed
readings will result. This can result in ineffective protection devices.
NOTE
The upper limits are not intended for continuous operation. Consult with
factory for detailed information assistance.
6.5 STOPPING
CAUTION
Venting the booster to pressures above cut-in while running can damage
the pump.
Stop the booster by turning off the motor. Isolate the booster from the vacuum system and vent the booster
to atmosphere. Turn off the cooling water if water cooled. Stop the backing pump. Refer to component
instruction manual.
6.6 STOPPING
CAUTION
Venting the booster to pressures above cut-in while running can damage
the pump.
Stop the booster by turning off the motor. Isolate the booster from the vacuum system and vent the booster
to atmosphere. Turn off the cooling water if water cooled. Stop the backing pump. Refer to component
instruction manual.
6.7 WATER INJECTED VACUUM BOOSTERS
Water injected into the inlet of a booster operating on vacuum service will cool the booster. The water
absorbs the heat of compression as it passes through the unit along with the air/gas being compressed.
A booster cooled in this manner can operate safely at higher vacuums or higher inlet temperatures than a
normally uncooled unit.
Summary of Contents for M-D Pneumatics 7010
Page 43: ...43 NOTES ...
Page 50: ...50 3200C CUTAWAY DRAWING 3200 90C 91C 92C 93C 1 OF 2 A ...
Page 51: ...51 3200C CONFIGURATIONS DRAWINGS 3200 90C 91C 92C 93C 2 of 2 A ...
Page 54: ...54 5500C CUTAWAY DRAWING 5500 90C 91C 92C 93C 1 OF 2 E OIL LEVEL SIGHT GAUGE DETAIL ...
Page 55: ...55 5500C CONFIGURATIONS DRAWINGS 5500 90C 91C 92C 93C 2 of 2 E ...
Page 56: ...56 7000C CUTAWAY DRAWING 7000 90C 91C 1 OF 3 ...
Page 57: ...57 7000C CONFIGURATIONS DRAWING 7000 90C 2 OF 3 ...
Page 58: ...58 7000C CONFIGURATIONS DRAWING 7000 91C 3 OF 3 7000 91C 7013 SHOWN ...
Page 68: ...68 NOTES ...