3. 

Wiring Instructions    

*NEVER CONNECT 110V AC DIRECTLY TO THE CONTROL BOARD.

 

The Turnstyle System is low voltage (12V DC), thereby eliminating the danger of electric shock.  Care should be taken 

however to guard against cuts and abrasions of the wire as this could cause a short circuit.  All wires should be passed through 
one of the strain relief fittings in the bottom of the Control Box.  Wires should be stripped back between 1/4” if needed.  The exposed 
ends are then inserted into the proper terminals in the wiring blocks and the screws tightened.  

a. Attach the Gate wires first.  If a single gate is installed, attach the wires to “Gate 1” terminal (

Blue

 wire on left, 

Brown

 wire on right), 

keeping in mind you may have to reverse polarity.  If dual gates are installed, attach the wires from either gate to “Gate 1” terminal 
and the other to “gate 2” terminal.

b. Next, attach the charging source(s) to the “Solar/AC” terminal.  These terminals are not polar.  You can attach an optional 12V solar 

panel or the included AC/AC wall transformer, an AC trickle charger, or both to the “Solar/AC” terminals.  These sources charge the 
12 volt battery.

c. Next, attach the 12V battery, paying close attention to wiring colors.

*Note: Before wiring other accessories, you should now proceed to the Adjustments section below to adjust 
the swing of the gates, polarity and sensitivity.

4. 

Adjustments

 

 

Now that you have installed and wired your gate(s), you must now make some adjustments; the opening and closing 

positions of the gate(s), the sensitivity of the gate(s) to obstructions, and Automatic Closing (Auto-Close) time (if desired).

1.

 

Open and Closed Positions of the Gates

 

Turnstyle Gate Operators are engineered to move 90 degrees in either direction.  Following your installation, 

your gates will most likely not open and close the way you want.  However, adjustment to the desired positioning is very 
simple.  First, direct your attention to the collar at the bottom of the operator(s).  On a pillar mount the collar is a part of 
the lower mounting bracket.  on a ground mount, the collar is a part of the ground sleeve (pictured below).  The collar 
has two Allen (hex head) screws.  Position the gate(s) in the closed position.  Tighten the Bottom Mount screws so that 
the gate(s) are level and will not swing freely.

a. With your keychain transmitter, press the button to activate the gate(s).  Note the direction of opening of each gate.  Press the 

button a second time to stop the gates before they hit any obstructions.  If a gate is not moving in the desired direction, reverse the 
wires for that gate on the Control Panel wiring block.  Again, press the transmitter button and allow the gate(s) to move until they 
completely stop.  The gate(s) will not be in the desired positions.  Do not press the button again because that will reverse the 
movement of the gate(s).

b. Loosen the collars at the bottom of the gate(s) until the gates move freely.  Position the gate(s) in the full 90 degree open position.   

Tighten the collars.  Press the transmitter button again and allow the gate(s) to fully close.  Loosen the collars and adjust the 
gate(s) to the final closed position.  Tighten the collars securely.  The gate(s) should now open and close to the desired positions.  
If the gate positions need any fine tuning, use the above procedure.

2. 

Sensitivity Adjustment

 

The sensitivity adjustments are round white potentiometers located in the upper right quadrant 

of the circuit board (pictured right). The sensitivity is preset at the factory for most applications.  It is 
intended to interrupt the operation of the system in the event the gate(s) encounter resistance such as 
striking an object or person.  However, because of wind load or the weight of the gate(s), you may need 
to adjust sensitivity.  To decrease sensitivity, turn the adjusting screw counter-clockwise.  To increase 
sensitivity, turn the adjusting screw clockwise.

Summary of Contents for Pillar Ground

Page 1: ...WWW TURNSTYLEGATES COM Foreign Domestic Patents Issued Pending 1 800 548 2212 1 Instruction Manual The Armless Gate Opener The Power Is In The Post Steel Model Pillar Ground Mount Operators...

Page 2: ...EDED FOR INSTALLATION 5 VI PRE INSTALLATION MEASUREMENTS 6 VII INSTALLATIONS 7 A Pillar Mount 7 B Ground Mount 10 VIII BRACKETS 12 IX ELECTRONICS 14 Control Panel 14 Wiring Terminal Functions 15 Wirin...

Page 3: ...entrapment protection 1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving 2 An automatic closing device such as a timer loop sensor or...

Page 4: ...four single family dwelling or a garage or parking area associated therewith Class II COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system intended for use in a commer...

Page 5: ...nd Mount operates as a stand alone installation in which the Turnstyle operator is set in the ground Each system is available in both Manual and Automatic configurations If your gate s are to be integ...

Page 6: ...WWW TURNSTYLEGATES COM Foreign Domestic Patents Issued Pending 1 800 548 2212 6 Turnstyle Pillar Mount GMS utilizing Gate Mounting Brackets Integrated Turnstyle Pillar Mount GMS...

Page 7: ...2 Mounting your Turnstyle Operator a Place Turnstyle operator into the lower bracket Loosen or remove the collar clamp from the lower bracket using a 5 16 hex wrench to increase ease of placing the in...

Page 8: ...pillar mount bracket onto pillar post Depending on the construction of your pillar post drill your pilot holes and securely attach the upper pillar mount bracket Make sure the bracket is securely atta...

Page 9: ...e correct location of the opposite lower pillar mount bracket is determined return to page 7 and follow installation instructions from Step 1 b Level lower pillar mount bracket At this point you have...

Page 10: ...the end of your fence section located on the highest ground elevation d Level Turnstyle operator and secure ground sleeve into ground Once the appropriate size hole has been prepared with the ground s...

Page 11: ...erator Return to page 10 and follow Ground Mount installation instructions from Step 1 a Determine location of your Turnstyle Ground mount GMS through Step 1 c Prepare concrete and then proceed below...

Page 12: ...wrench Note Unicorn brackets have two nuts one on either side of the gate frame which provide a measurement adjustment feature by tightening and or loosening the nuts in order to prevent gaps between...

Page 13: ...drilled holes in the wood gate and tighten to secure your wood gate onto the Turnstyle gate operator Thru bolts can also be used Optional The holes can be drilled directly into the wood gate through...

Page 14: ...Control Board b Sensitivity Adjustment Potentiometers small round white controls with adjusting screw heads located in the upper right quadrants of the Control Board c Fuses located on bottom left si...

Page 15: ...ection if gate was closing EMER VEH Emergency Vehicle Opener Input for Emergency Vehicle Opener Activation will open the gate Continuous activation will prevent the gate from automatically closing EXI...

Page 16: ...nd close the way you want However adjustment to the desired positioning is very simple First direct your attention to the collar at the bottom of the operator s On a pillar mount the collar is a part...

Page 17: ...the Power Bolt Lock Opening Down Switch 6 will enable the Power Bolt Lock or Magnetic Lock as selected Note If after enabling the Auto Close feature you find the gates are automatically opening rathe...

Page 18: ...ntil the power bolt lock is completely open The power bolt lock is wired into the terminal labeled LOCK Polarity is critical Before mounting your lock to your gates follow the below sequence to ensure...

Page 19: ...OUR GATE MANUAL THE KEYFOB TRANSMITTER WORKS ONLY AT A SHORT DISTANCE 1 TRANSMITTER BATTERY LOW REPLACE BATTERY 2 RECEPTION IS BEING BLOCKED AN EXTERNAL ANTENNA MAY BE NECESSARY ONLY ONE GATE WILL OPE...

Page 20: ...e manufacturer will pay standard ground freight on the return of repaired or replaced items in warranty TURNSTYLE AUTOMATIC GATE OPERATOR TURNSTYLE ENTERPRISES INC LIMITED WARRANTY Warranty V 2 1 V 2...

Reviews: