The control panel to your Turnstyle Gate Operating System allows the
employment of various optional devices.
1.
Solar Panel
- A solar panel is an optional battery charging device.
The solar panel wires
are connected to the terminal block labeled “Solar/AC.” Polarity is not critical. Be sure the
solar panel is facing south for maximum exposure to sunlight.
2.
Exit Devices
- Various exit devices can be used to open your gate(s) upon exit. These include exit wands,
loop detectors and optical sensors. These devices should be wired into the terminal labeled “ED.” Wiring
instructions are provided with each of these devices.
3.
Lights
(low voltage) - Low voltage lights add beauty as well as function. They are wired
directly into the terminal block labeled “Light.” The lights come on when the gate is activated
and remain on for approximately 30 seconds after the cycle completes. They also visually relay
critical system information such as battery conditions and sensor actions.
4.
Contact Sensors
- Contact sensors are sensitive strips attached to either the front, back, or both edges
of the opening end of a gate. Contact sensors will stop the movement of a gate immediately upon contacting
an object or person. A front edge contact sensor must be connected to the “CSF” terminal and back edge
contact sensor must be connected to the “CSB” terminal.
5.
Power Lock
- The power bolt lock is designed to close four (4) seconds after the gate(s) complete
their close cycle. The gate opening cycle will not begin until the power bolt lock is completely open.
The power bolt lock is wired into the terminal labeled “LOCK.” Polarity is critical. Before mounting
your lock to your gates, follow the below sequence to ensure proper installation and functioning.
a. First establish that your gates are opening and closing correctly. (See “Adjustments”, p.16).
If you are employing the “Auto-close” feature, follow the “Auto-close Adjustment” instruction on p. 17.
b. Extend the bolt on your lock by touching the wires to the battery terminals (
Brown
wire to the Positive
RED
Terminal,
Blue
wire to the Negative BLACK Terminal). With the gates in the closed position, wire the lock to the control panel at the
terminal marked “LOCK” and lay it on the ground. Now, open your gates and close them. The lock bolt should retract
when the gates are opened and extend 4 seconds after the gates are fully closed.
c. If the lock works in reverse of the open/close cycle, simply reverse the wires on the board to change the polarity.
Once the lock opens and closes in sync with the gate(s) it is safe to mount your lock; (See p. 17).
6.
Key Pads
- The wireless key pad is designed to work with the wireless receiver, already installed
in your control box electronics enclosure. Follow the instructions provided with the wireless keypad
for programming. No further wiring is required. Hard wired key pads should be connected to the
terminal marked “K” on the control panel. Refer to the instructions provided with the wired keypad
for programming.
7.
Emergency Vehicle Opening Devices
- The “EVO” terminal on the control panel is reserved for
emergency vehicle opening devices for admittance of fire and other emergency vehicles. Check
with local fire, police and municipal authorities for EVO requirements.