Turnstyle Enterprises wishes to emphasize that safety always comes first.  It is of the utmost importance that the 

correct installation guidelines be followed during assembly and that all people and objects be kept clear of potential 
entrapment areas.  Please read the following safety guidelines before performing your installation. 

Before beginning your installation, make sure that your gates and gate opener installation comply with applicable local codes.

Installation Safety for Automatic Gates

a

. Install the gate opener only when: 

 

1. The operator is appropriate for the construction of the gate and the usage Class of the gate.

 

2. All exposed pinch points are eliminated or guarded.

b.

The operator is intended for installation only on gates used for vehicles.  Pedestrians must be supplied with a separate access 
opening.  The pedestrian access opening shall be designed to promote pedestrian usage.  Locate the gate such that persons will 
not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

c.

The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when 
opening and closing to reduce risk of entrapment.  Swinging gates shall not open into public access areas.

d.

The gate must be properly installed and work freely in both directions prior to the final adjustment of the operator and connection to 
the power supply.  

e.

Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the 
user is prevented from reaching over, under, around or through the gate to operate the controls.  Outdoor or easily accessible 
controls shall have a security feature to prevent unauthorized use.

f.

The Stop and/or Reset button must be located in the line-of-sight of the gate.  Activation of the reset control shall not cause the 
operator to start.

g.

A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.

 [Warning signs have 

been supplied with the Turnstyle operator.]

[FOR USERS AND INSTALLERS UTILIZING TYPE “D” ENTRAPMENT PROTECTION, NON-CONTACT SENSORS AND 
CONTACT SENSORS, THE FOLLOWING ADDITIONAL SAFETY CONCERNS APPLY.  MORE DETAILED TREATMENT MAY 
BE FOUND IN UNDERWRITERS LABORATORIES SPECIFICATION 325 (UL 325).]

a. For gate operators utilizing Type D [entrapment] protection:
 

1. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving.

 

2. An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and

 

3. No other activation device shall be connected.

b. For gate operators utilizing non-contact sensor, refer to UL 325, Section 31.1.1:

 

1. See instructions on the placement of non-contact sensors for each type of application. 

 

2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is 

                   moving, and

 

3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the

                  perimeter reachable by a moving gate or barrier.
c. For a gate operator utilizing a contact sensor, refer to UL 325, Section 31.1.1:

 

1. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and

                  the gate operator is not subjected to mechanical damage.

 

2. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment 

                  protection functions shall be located where the transmission of the signals are not obstructed or impeded by building  
                  structures, natural landscaping or similar obstruction.  A wireless contact sensor shall function under the intended end-use
                  conditions.

 

3. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate.  Additionally, if the

                  bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or 
                  more contact sensors shall be located on the bottom edge.

Operational Safety For Automatic Gates

WARNING - To reduce the risk of injury or death:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2.

Never let children operate or play with gate controls.  Keep the remote control away from children.

3.

Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4.

Test the gate operator monthly.  The gate MUST reverse on contact with a rigid object or stop when an object activates the non-
contact sensors.  After adjusting the force or the limit of travel, retest the gate operator.  Failure to adjust the gate operator properly 
can increase the risk of injury or death.

5.

Use the emergency release only when the gate is not moving.

6.

KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.  Have a qualified service person make repairs to the gate 
hardware.

7.

The entrance is for vehicles only. Pedestrians must use separate entrance.

8.

SAVE THESE INSTRUCTIONS.

Safety Considerations

Summary of Contents for Pillar Ground

Page 1: ...WWW TURNSTYLEGATES COM Foreign Domestic Patents Issued Pending 1 800 548 2212 1 Instruction Manual The Armless Gate Opener The Power Is In The Post Steel Model Pillar Ground Mount Operators...

Page 2: ...EDED FOR INSTALLATION 5 VI PRE INSTALLATION MEASUREMENTS 6 VII INSTALLATIONS 7 A Pillar Mount 7 B Ground Mount 10 VIII BRACKETS 12 IX ELECTRONICS 14 Control Panel 14 Wiring Terminal Functions 15 Wirin...

Page 3: ...entrapment protection 1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving 2 An automatic closing device such as a timer loop sensor or...

Page 4: ...four single family dwelling or a garage or parking area associated therewith Class II COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system intended for use in a commer...

Page 5: ...nd Mount operates as a stand alone installation in which the Turnstyle operator is set in the ground Each system is available in both Manual and Automatic configurations If your gate s are to be integ...

Page 6: ...WWW TURNSTYLEGATES COM Foreign Domestic Patents Issued Pending 1 800 548 2212 6 Turnstyle Pillar Mount GMS utilizing Gate Mounting Brackets Integrated Turnstyle Pillar Mount GMS...

Page 7: ...2 Mounting your Turnstyle Operator a Place Turnstyle operator into the lower bracket Loosen or remove the collar clamp from the lower bracket using a 5 16 hex wrench to increase ease of placing the in...

Page 8: ...pillar mount bracket onto pillar post Depending on the construction of your pillar post drill your pilot holes and securely attach the upper pillar mount bracket Make sure the bracket is securely atta...

Page 9: ...e correct location of the opposite lower pillar mount bracket is determined return to page 7 and follow installation instructions from Step 1 b Level lower pillar mount bracket At this point you have...

Page 10: ...the end of your fence section located on the highest ground elevation d Level Turnstyle operator and secure ground sleeve into ground Once the appropriate size hole has been prepared with the ground s...

Page 11: ...erator Return to page 10 and follow Ground Mount installation instructions from Step 1 a Determine location of your Turnstyle Ground mount GMS through Step 1 c Prepare concrete and then proceed below...

Page 12: ...wrench Note Unicorn brackets have two nuts one on either side of the gate frame which provide a measurement adjustment feature by tightening and or loosening the nuts in order to prevent gaps between...

Page 13: ...drilled holes in the wood gate and tighten to secure your wood gate onto the Turnstyle gate operator Thru bolts can also be used Optional The holes can be drilled directly into the wood gate through...

Page 14: ...Control Board b Sensitivity Adjustment Potentiometers small round white controls with adjusting screw heads located in the upper right quadrants of the Control Board c Fuses located on bottom left si...

Page 15: ...ection if gate was closing EMER VEH Emergency Vehicle Opener Input for Emergency Vehicle Opener Activation will open the gate Continuous activation will prevent the gate from automatically closing EXI...

Page 16: ...nd close the way you want However adjustment to the desired positioning is very simple First direct your attention to the collar at the bottom of the operator s On a pillar mount the collar is a part...

Page 17: ...the Power Bolt Lock Opening Down Switch 6 will enable the Power Bolt Lock or Magnetic Lock as selected Note If after enabling the Auto Close feature you find the gates are automatically opening rathe...

Page 18: ...ntil the power bolt lock is completely open The power bolt lock is wired into the terminal labeled LOCK Polarity is critical Before mounting your lock to your gates follow the below sequence to ensure...

Page 19: ...OUR GATE MANUAL THE KEYFOB TRANSMITTER WORKS ONLY AT A SHORT DISTANCE 1 TRANSMITTER BATTERY LOW REPLACE BATTERY 2 RECEPTION IS BEING BLOCKED AN EXTERNAL ANTENNA MAY BE NECESSARY ONLY ONE GATE WILL OPE...

Page 20: ...e manufacturer will pay standard ground freight on the return of repaired or replaced items in warranty TURNSTYLE AUTOMATIC GATE OPERATOR TURNSTYLE ENTERPRISES INC LIMITED WARRANTY Warranty V 2 1 V 2...

Reviews: