Cleaning, servicing and maintenance
6-59
6.7
Bolt torques
Thread
A=Ø
Spanner gap
[mm]
Torque [Nm]
depending on the bolt / nut quality classification
8.8
10.9
12.9
M 8
13
25
35
41
M 8x1
27
38
41
M 10
16 (17)
49
69
83
M 10x1
52
73
88
M 12
18 (19)
86
120
145
M 12x1.5
90
125
150
M 14
22
135
190
230
M 14x1.5
150
210
250
M 16
24
210
300
355
M 16x1.5
225
315
380
M 18
27
290
405
485
M 18x1.5
325
460
550
M 20
30
410
580
690
M 20x1.5
460
640
770
M 22
32
550
780
930
M 22x1.5
610
860
1050
M 24
36
710
1000
1200
M 24x2
780
1100
1300
M 27
41
1050
1500
1800
M 27x2
1150
1600
1950
M 30
46
1450
2000
2400
M 30x2
1600
2250
2700
•
Check the bolts and nuts for tight seating for the first time after 5 operating hours,
then regularly (approx. every 50 operating hours); tighten up if required.
A
= Thread size (tensile strength
classification found on bolt head)
Fig. 6.14
Summary of Contents for PLUS 560