35
5055.48-A 170915-44
TN24.BODYA
Fan Replacement
Removal
1. Turn off the main gas supply to gas stove and disconnect the
gas supply from the 3/8” fl are fi tting.
Also, disconnect the power cord from the unit.
2. Remove rear cover to gain access to the fans.
3. Remove the three (3) screws from the panel as
shown in (Figure 81) inset and extract the fan.
You will have to disconnect the wires from the
fan before you can completely remove the fan.
4. Retain rubber grommets and plastic
bushings (Figure 82) for installation
of new fan.
Screw
Screws
Installation
Installation is the reverse of removal
Note:
The two fans are inverse to each other.
There is a left fan and a right fan and
therefore they have different part numbers
on their labels (Figure 82) & (Figure 83).
See replacement parts list (page 39) for
part numbers.
NOTE: Fan manufacturers part numbers are
as follows:
SA-25L-1027 = Right fan
SA-25L-1026 = Left Fan
Installer Information
Figure 80: Fan location.
Figure 81: Fan location (inset).
Figure 82: Fan motor
1026 (left).
Figure 83: Fan motor
1027 (right).
Figure 84: Grommet
and plastic bushing.