31
5055.48-A 170915-44
TN24.BODYA
Burner Installation
Burner Installation/Removal
Installation
Fit the burner over the orifice (Figure 70) & (Figure 71) and set so that the screw holes on both sides of
the burner are making full contact with the back panel (Figure 72).
Venturi Adjustment
Adjustment
Loosen the wing nut and move post up to
open venturi, and down to close venturi.
Tighten wing-nut once adjustment is
complete.
Note: Venturi should be closed when using
natural gas and open when using liquid
propane.
Venturi adjustment is accessible through
an opening in the rear cover (Figure 31 on
page 20).
Some adjustment may be required
Damper Adjustment
Damper Adjustment
(Factory setting is closed; slowly open and adjust
as necessary to eliminate a sagging, sooting
flame).
Damper adjustment is located under the top
cladding cover plate.
back
panel
Installer Information
Figure 69: True north 24 Damper.
Figure 70: True north 24
burner orifice.
Figure 71: Burner insertion
over orifice.
Figure 72:
Burner flush against
back panel.
Figure 73: Venturi adjustment.