33
5055.48-A 170915-44
TN24.BODYA
Note: To test the gas pressure, turn off the gas supply to the gas stove before loosening test
point screws. Verify gas pressures with the gas stove lit and at the highest setting.
1. Remove back panel and locate the valve as seen in (Figure 75).
2. Locate the inlet and outlet test points on the valve which can be seen in (Figure 76).
After locating test ports loosen the screws within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports.
4. Turn gas supply back on and test pressures.
5. After testing is finished, turn off gas supply, remove the pressure gauges and retighten the
the test point screws .
The pilot flame level can be
adjusted by turning the adjustment
screw located on the valve in
(Figure 76)
Gas Pressure Testing Procedure
Pilot Flame Adjustment
Pilot adjustment
screw
Pressure
modulator
device
Main gas
solenoid
Pilot
solenoid
Inlet pressure test
point
Outlet pressure test
point
Installer Information
Figure 74: True north 24
Pilot assembly.
Figure 75: Control valve
location.
Figure 76: Gas
control
valve.