E X P L O S I O N P R O O F
135
ExBin- FR...
68
157,5
117
166
80
107
55
66
~ 180
Ø 4,5
Ø 4,5
Ø 4,5
www.schischek.com
Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected]
ExBin-FR_en
V01 – 9-Nov-2016
Technical data
ExBin ...-FR3 ...-FR6
Accessories
MKR
Mounting bracket for round ducts up to Ø 600 mm
Installation Kit 1.3 Assembly cramp and 4 assembly brackets for ...Bin-FR3
Installation Kit 1.6 Assembly cramp and 8 assembly brackets for ...Bin-FR6
Dimensions
[mm]
Approbationen
ATEX directive
2014/34/EU
EC type-approved
EPS 14 ATEX 1 657
IECEx certified
IECEx EPS 14.0074
Approval for gas
II 2 (1) G Ex e mb [ia Ga] IIC T6 Gb
Types ...-CT II 2 (1) G Ex e mb [ia Ga] IIB T6 Gb
Approval for dust
II 2 (1) D Ex tb [ia Da] IIIC T80°C Db IP66
CE identification CE
№
0158
EMC directive
2014/30/EU
Enclosure protection IP66 in acc. with EN 60529
EAC
TC RU С-DE.ГБ08.В.01510
Supply voltage, frequency
24 VAC/DC ±20 % (19,2...28,8 VAC/DC), 50/60 Hz
Current, power consumption
150 mA, ~ 4 W, internal fuse 500 mAT, not removable
Galvanic isolation
Supply for relay output min. 1,5 kV
Electrical connection
Terminals 0,14...2,5 mm² at integrated Ex-e terminal box, stripping length 9 mm, torque 0,4...0,5 Nm, equipotential bonding 4 mm²
Cable glands
2 × M16 × 1,5 mm, Ex-e approved, for cable diameter ~ Ø 5...9 mm
...-CT
2 × M16 × 1,5 mm, Ex-e approved, brass nickel-plated, for cable diameter ~ Ø 6...10 mm
Control elements
Rotary control for setpoint adjustment and fixing screw
Measuring range
Setpoint adjustable −10 °C...+15 °C
Status indication
via LEDs – GREEN: ambient temperature is above setpoint (normal), RED: ambient temperature is below setpoint
Housing material
Aluminium die-cast housing, coated. Optional with seawater resistant coating (...-CT)
Dimensions (L × B × H)
~ 180 × 107 × 66 mm (without connectors)
Weight
~ 950 g
Ambient temperature
−20...+50 °C
, capillary max. +80 °C, storage temperature
−35...+70 °C
Temperature class
T6 (T80 °C) bei
−
20...+50 °C
Ambient humidity
0...95 % rH, non condensing
Sensor circuit
Internal intrinsically safe (IS) circuit
Capillary Length
3 m ±15 cm
6 m ±20 cm
min. active length ~ 40 cm
min. bending radius 2 cm
Hysteresis
~ 6 K, accurancy of setpoints ±3 K
Start delay
5 s
Output
Potential free switching contact – breaking contact
max. rating load
0,5 A (30 VAC/DC) – 0,1 A (250 VAC) – 0,1 A (220 VDC)
min. rating load
10 mW / 0,1 V / 1 mA
Duration of life mechanical
10 × 10
6
electrical (rated load) 100 × 10
3
Wiring diagram
SB 1.0
Scope of delivery
Frost protection thermostat, self-tapping screws 4,2 × 13 mm resp. in stainless steel (with ...CT versions)
2 / 3