background image

8

EN

dehumidifier TTR 50 E

Operation

After being switched on, the device operates fully
automatically – depending on the selected operating mode
or until the float indicates that the condensation tank is full
and the device switches itself off.

Avoid open doors and windows.

Operating elements

10

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

11

12

9

No. Designation

Meaning

9

Swing 

LED

Illuminated when swing function is
activated

10

Swing

 button

Switching the swing function on or off

11

Anion 

LED

Illuminated when ionizer function is
activated

12

Anion 

button

Switching the ionization function on and
off

13

60 

% relative

humidity 

LED

Is illuminated when a relative humidity
level of 60 % is set

14

50 

% relative

humidity 

LED

Is illuminated if a relative humidity of
50 % is set

15

Humidity

 button Switching continuous operation on or off

Setting the relative humidity level (50 %
or 60 % RH)

16

4 h timer 

LED

Illuminated when the timer is activated:
4 h

17

2 h timer 

LED

Illuminated when the timer is activated:
2 h

18

Timer

 button

Switching the timer function on or off

19

Med

 LED

Illuminated when a medium fan speed is
set

20

Low

 LED

Illuminated when a low fan speed is set

21

Speed

 button

Setting the fan speed

22

Run

 LED

Is illuminated in green when the device
has been switched on

No. Designation

Meaning

23

Full

 LED

Is illuminated when the condensation
tank is full or not positioned properly.

24

On/off

 button

Switching the device on or off

25

Power

 LED

Is illuminated in red = standby or when
tilt protection has been triggered

26

High

 LED

Illuminated when a high fan speed is set

27

8 h timer 

LED

Illuminated when the timer is activated:
8 h

28

Continuous

 LED Is illuminated when continuous operation

is activated.

29

Humidity level

indication

Indication of the current room humidity
level

Switching the device on

Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.

Note

Wait for 3 minutes before you switch the device back
on (e.g. after draining the condensation tank).

1. Use the 

On/Off

 button (

24

) to switch the device on.

ð

The 

Run

 LED (

22

) is illuminated.

Setting the operating mode

Ventilation mode

The device can be set to three fan speeds: 

low

med

 and 

high

.

Low

:

The device operates at low fan speed to save energy and keep
the operating noise to a minimum.

Med

:

The device operates at normal fan speed.

High

:

The device operates at high fan speed.
Select the fan speed as follows:

1. Press the 

Speed

 button (

21

) until the desired LED for the

fan speed is lit.

Summary of Contents for TTR 50 E

Page 1: ...TRT BA TTR50E TC220609TTRT01 001 EN TTR 50 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...ways store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in ele...

Page 3: ...igns stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose...

Page 4: ...electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable o...

Page 5: ...ndensate can be discharged via a condensation hose connected to the connection opening The drier air thus conditioned is fed back to the room air via the air outlet The drier air mixes with the air in...

Page 6: ...wer cable out of the mains socket When the device is not being used observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an...

Page 7: ...iving rooms a relative humidity of approx 50 to 60 is sufficient In storage facilities and archives the humidity should not exceed approx 50 Inserting the air filter Note Do not operate the device wit...

Page 8: ...speed is set 21 Speed button Setting the fan speed 22 Run LED Is illuminated in green when the device has been switched on No Designation Meaning 23 Full LED Is illuminated when the condensation tank...

Page 9: ...Press the Swing button 10 The Swing LED 9 is illuminated The swing function is activated 2 Press the Swing button 10 again to deactivate the swing function The Swing LED 9 goes out Setting the timer...

Page 10: ...e hose must not be kinked Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Press the On Off button 24 Wait for 4 minutes Due to the rundown time of the interna...

Page 11: ...ondensation tank for dirt If necessary clean the condensation tank The float must be able to move freely Check the room temperature and the current room humidity level If the current room humidity lev...

Page 12: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 13: ...ol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the insi...

Page 14: ...condensation tank 5 over a drain or sink 4 Rinse the condensation tank 5 with clear water Clean the condensation tank 5 at regular intervals using a mild cleaning agent no detergent 5 Reattach the cov...

Page 15: ...pter Technical annex Technical data Parameter Value Model TTR 50 E Max dehumidification performance 7 5 l 24 h Dehumidification performance 30 C and 80 RH 7 l Amount of air 126 m h Operating range tem...

Page 16: ...16 EN dehumidifier TTR 50 E Wiring diagram...

Page 17: ...cover A 2 47 Anti fall switch 6 Gear 1 26 Rubber sac 48 Motor capacitor 7 Shield electrode 27 Heat exchanger cover B 2 49 Humidification sensor 8 Magnet of counter component cover 28 Heat exchanger co...

Page 18: ...ut other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment auth...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: