Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The mains connection must correspond to the
specifications in the Technical annex.

Insert the mains plug into a properly fused mains socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Never insert any objects or limbs into the device.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:

dehumidifying and drying:

– living rooms, bedrooms and basements
– holiday homes, camper vans

maintaining the dryness of:

– storage spaces, archives, laboratories, garages
– changing rooms etc.

Foreseeable misuse

The device is not intended for industrial use.

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device out of doors.

Do not use the device in wet rooms (e.g. bathrooms or
laundry rooms).

Never immerse the device in water.

Do not make any unauthorised modifications, alterations or
structural changes to the device.

Any use other than the intended use is regarded as a
reasonably foreseeable misuse.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Summary of Contents for TTR 50 E

Page 1: ...TRT BA TTR50E TC220609TTRT01 001 EN TTR 50 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...ways store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in ele...

Page 3: ...igns stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose...

Page 4: ...electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable o...

Page 5: ...ndensate can be discharged via a condensation hose connected to the connection opening The drier air thus conditioned is fed back to the room air via the air outlet The drier air mixes with the air in...

Page 6: ...wer cable out of the mains socket When the device is not being used observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an...

Page 7: ...iving rooms a relative humidity of approx 50 to 60 is sufficient In storage facilities and archives the humidity should not exceed approx 50 Inserting the air filter Note Do not operate the device wit...

Page 8: ...speed is set 21 Speed button Setting the fan speed 22 Run LED Is illuminated in green when the device has been switched on No Designation Meaning 23 Full LED Is illuminated when the condensation tank...

Page 9: ...Press the Swing button 10 The Swing LED 9 is illuminated The swing function is activated 2 Press the Swing button 10 again to deactivate the swing function The Swing LED 9 goes out Setting the timer...

Page 10: ...e hose must not be kinked Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Press the On Off button 24 Wait for 4 minutes Due to the rundown time of the interna...

Page 11: ...ondensation tank for dirt If necessary clean the condensation tank The float must be able to move freely Check the room temperature and the current room humidity level If the current room humidity lev...

Page 12: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 13: ...ol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the insi...

Page 14: ...condensation tank 5 over a drain or sink 4 Rinse the condensation tank 5 with clear water Clean the condensation tank 5 at regular intervals using a mild cleaning agent no detergent 5 Reattach the cov...

Page 15: ...pter Technical annex Technical data Parameter Value Model TTR 50 E Max dehumidification performance 7 5 l 24 h Dehumidification performance 30 C and 80 RH 7 l Amount of air 126 m h Operating range tem...

Page 16: ...16 EN dehumidifier TTR 50 E Wiring diagram...

Page 17: ...cover A 2 47 Anti fall switch 6 Gear 1 26 Rubber sac 48 Motor capacitor 7 Shield electrode 27 Heat exchanger cover B 2 49 Humidification sensor 8 Magnet of counter component cover 28 Heat exchanger co...

Page 18: ...ut other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment auth...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...