Overview of spare parts

Note:

 The position numbers of the spare parts differ from those

describing the positions of other parts mentioned in this
operating manual.

No. Spare Part

No. Spare Part

No. Spare Part

1

Front cover

19

Top cover

42

Air duct II

2

Centrifugal rotor

22

Back cover

44

Anti fall switch seating

3

Wheel cover

23

Guide rail I/II

45

Microswitch

4

Shade-pode ventor

24

Heat exchanger cover A 1

46

Line pressing code

5

Synchronous motor

25

Heat exchanger cover A 2

47

Anti-fall switch

6

Gear 1

26

Rubber sac

48

Motor capacitor

7

Shield electrode

27

Heat exchanger cover B 2

49

Humidification sensor

8

Magnet of counter component
cover

28

Heat exchanger cover B 1

50

Power line

9

Counter component cover

29

Wheel bracket

51

Paster

10

Pin board

30

Hingle

53

High temperature thermistor

11

Dehumidification wheel

31

Heating element

54

Wheel sleeve

12

Gear II

35

Water level float

55

Sheeting

13

Electric control box

36

Water tank cover

56

Foot pads

14

Fixed fan bracket

37

Nut

57

Nut

15

Air deflector

38

Water tank

58

Gasket

16

Stepper motor

39

Shade pole motor

59

Power pack cover

17

Control panel

40

Air duct I

18

Button panel

41

Centrifugal rotor

Summary of Contents for TTR 50 E

Page 1: ...TRT BA TTR50E TC220609TTRT01 001 EN TTR 50 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...ways store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in ele...

Page 3: ...igns stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose...

Page 4: ...electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable o...

Page 5: ...ndensate can be discharged via a condensation hose connected to the connection opening The drier air thus conditioned is fed back to the room air via the air outlet The drier air mixes with the air in...

Page 6: ...wer cable out of the mains socket When the device is not being used observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an...

Page 7: ...iving rooms a relative humidity of approx 50 to 60 is sufficient In storage facilities and archives the humidity should not exceed approx 50 Inserting the air filter Note Do not operate the device wit...

Page 8: ...speed is set 21 Speed button Setting the fan speed 22 Run LED Is illuminated in green when the device has been switched on No Designation Meaning 23 Full LED Is illuminated when the condensation tank...

Page 9: ...Press the Swing button 10 The Swing LED 9 is illuminated The swing function is activated 2 Press the Swing button 10 again to deactivate the swing function The Swing LED 9 goes out Setting the timer...

Page 10: ...e hose must not be kinked Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Press the On Off button 24 Wait for 4 minutes Due to the rundown time of the interna...

Page 11: ...ondensation tank for dirt If necessary clean the condensation tank The float must be able to move freely Check the room temperature and the current room humidity level If the current room humidity lev...

Page 12: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 13: ...ol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the insi...

Page 14: ...condensation tank 5 over a drain or sink 4 Rinse the condensation tank 5 with clear water Clean the condensation tank 5 at regular intervals using a mild cleaning agent no detergent 5 Reattach the cov...

Page 15: ...pter Technical annex Technical data Parameter Value Model TTR 50 E Max dehumidification performance 7 5 l 24 h Dehumidification performance 30 C and 80 RH 7 l Amount of air 126 m h Operating range tem...

Page 16: ...16 EN dehumidifier TTR 50 E Wiring diagram...

Page 17: ...cover A 2 47 Anti fall switch 6 Gear 1 26 Rubber sac 48 Motor capacitor 7 Shield electrode 27 Heat exchanger cover B 2 49 Humidification sensor 8 Magnet of counter component cover 28 Heat exchanger co...

Page 18: ...ut other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment auth...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: