dehumidifier TTR 50 E

Setting the desired relative room humidity

You can set a desired relative room humidity level of 50 % 
or 60 %. To do so, please proceed as follows:

1. Press the 

Humidity

 button (

15

) until the desired room

humidity level has been set.

ð

The humidity level indication (

29

) shows the value for

the current room humidity level.

Continuous operation

The device dehumidifies the air constantly and regardless of the
relative humidity.
The desired relative room humidity cannot be adjusted in this
operating mode.

1. Press the 

Humidity

 button(

15

) until the

Continuous

 LED (

28

) is illuminated.

Ionization function

With this function, the room air is not only cleaned by means of
the air filter, but additionally by means of anions. The released
anions remove pollen, dust, viruses and bacteria from the room
air.

1. Press the 

Anion

 button (

12

).

ð

The 

Anion

 LED (

11

) is illuminated.

ð

The ionization function is switched on.

2. Press the 

Anion 

button (

12

) again to deactivate the

ionization function.

ð

The 

Anion

 LED (

11

) goes out.

Swing function

With the swing function being switched on, the air flaps move
automatically and ensure continuous air circulation. The air
circulates out of the device from the top.

1. Press the 

Swing

 button (

10

).

ð

The 

Swing

 LED (

9

) is illuminated.

ð

The swing function is activated.

2. Press the 

Swing

 button (

10

) again to deactivate the swing

function.

ð

The Swing LED (

9

) goes out.

Setting the timer

For the device to switch off automatically after a predefined
number of hours (2, 4 or 8 hours) you can program the timer.

Note

The device must not be left unattended in a freely
accessible room with an activated timer.

Automatic switch-off

ü

The device is switched on.

1. Press the 

Timer

 button (

18

) until the 2 h Timer LED (

17

),

the 4 h Timer LED (

16

) or the 8 h Timer LED (

27

) is

illuminated.

ð

After the predefined time, the device switches itself off.

Notes regarding automatic switch-off:

Manually switching the device off disables the automatic
switch-off function.

The device switches off automatically when the
condensation tank is full, even if the timer is active. Once
the water tank has been emptied, the device continues
counting down the remaining hours of the timer.

Operation with hose attached to the condensation
connection

At a high humidity level it is recommendable to constantly drain
the condensate via a hose, for otherwise the condensation tank
has to be emptied too frequently. The hose is not included in the
scope of delivery.
To do so, proceed as follows:

ü

A suitable hose (diameter: 14 mm) is ready for use.

ü

The device is switched off.

1. Remove the condensation tank (

5

) with cover (

30

).

5

30

Summary of Contents for TTR 50 E

Page 1: ...TRT BA TTR50E TC220609TTRT01 001 EN TTR 50 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...ways store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in ele...

Page 3: ...igns stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose...

Page 4: ...electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable o...

Page 5: ...ndensate can be discharged via a condensation hose connected to the connection opening The drier air thus conditioned is fed back to the room air via the air outlet The drier air mixes with the air in...

Page 6: ...wer cable out of the mains socket When the device is not being used observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an...

Page 7: ...iving rooms a relative humidity of approx 50 to 60 is sufficient In storage facilities and archives the humidity should not exceed approx 50 Inserting the air filter Note Do not operate the device wit...

Page 8: ...speed is set 21 Speed button Setting the fan speed 22 Run LED Is illuminated in green when the device has been switched on No Designation Meaning 23 Full LED Is illuminated when the condensation tank...

Page 9: ...Press the Swing button 10 The Swing LED 9 is illuminated The swing function is activated 2 Press the Swing button 10 again to deactivate the swing function The Swing LED 9 goes out Setting the timer...

Page 10: ...e hose must not be kinked Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Press the On Off button 24 Wait for 4 minutes Due to the rundown time of the interna...

Page 11: ...ondensation tank for dirt If necessary clean the condensation tank The float must be able to move freely Check the room temperature and the current room humidity level If the current room humidity lev...

Page 12: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 13: ...ol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the insi...

Page 14: ...condensation tank 5 over a drain or sink 4 Rinse the condensation tank 5 with clear water Clean the condensation tank 5 at regular intervals using a mild cleaning agent no detergent 5 Reattach the cov...

Page 15: ...pter Technical annex Technical data Parameter Value Model TTR 50 E Max dehumidification performance 7 5 l 24 h Dehumidification performance 30 C and 80 RH 7 l Amount of air 126 m h Operating range tem...

Page 16: ...16 EN dehumidifier TTR 50 E Wiring diagram...

Page 17: ...cover A 2 47 Anti fall switch 6 Gear 1 26 Rubber sac 48 Motor capacitor 7 Shield electrode 27 Heat exchanger cover B 2 49 Humidification sensor 8 Magnet of counter component cover 28 Heat exchanger co...

Page 18: ...ut other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment auth...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: