background image

EN

13

dehumidifier TTR 50 E

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.

Safety signs and labels on the device

Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the

device cleaned by a specialist company for cooling and air-
conditioning or by Trotec.

5. Put the air filter back in.

Cleaning the air filter

Note

Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!

The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).

1. Remove the air filter from the device.

2. Clean the filter using a slightly damp, soft, lint-free cloth. If

the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.

3. Allow the filter to dry completely. Do not insert a wet filter

into the device!

Summary of Contents for TTR 50 E

Page 1: ...TRT BA TTR50E TC220609TTRT01 001 EN TTR 50 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...ways store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in ele...

Page 3: ...igns stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose...

Page 4: ...electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable o...

Page 5: ...ndensate can be discharged via a condensation hose connected to the connection opening The drier air thus conditioned is fed back to the room air via the air outlet The drier air mixes with the air in...

Page 6: ...wer cable out of the mains socket When the device is not being used observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an...

Page 7: ...iving rooms a relative humidity of approx 50 to 60 is sufficient In storage facilities and archives the humidity should not exceed approx 50 Inserting the air filter Note Do not operate the device wit...

Page 8: ...speed is set 21 Speed button Setting the fan speed 22 Run LED Is illuminated in green when the device has been switched on No Designation Meaning 23 Full LED Is illuminated when the condensation tank...

Page 9: ...Press the Swing button 10 The Swing LED 9 is illuminated The swing function is activated 2 Press the Swing button 10 again to deactivate the swing function The Swing LED 9 goes out Setting the timer...

Page 10: ...e hose must not be kinked Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Press the On Off button 24 Wait for 4 minutes Due to the rundown time of the interna...

Page 11: ...ondensation tank for dirt If necessary clean the condensation tank The float must be able to move freely Check the room temperature and the current room humidity level If the current room humidity lev...

Page 12: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 13: ...ol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the insi...

Page 14: ...condensation tank 5 over a drain or sink 4 Rinse the condensation tank 5 with clear water Clean the condensation tank 5 at regular intervals using a mild cleaning agent no detergent 5 Reattach the cov...

Page 15: ...pter Technical annex Technical data Parameter Value Model TTR 50 E Max dehumidification performance 7 5 l 24 h Dehumidification performance 30 C and 80 RH 7 l Amount of air 126 m h Operating range tem...

Page 16: ...16 EN dehumidifier TTR 50 E Wiring diagram...

Page 17: ...cover A 2 47 Anti fall switch 6 Gear 1 26 Rubber sac 48 Motor capacitor 7 Shield electrode 27 Heat exchanger cover B 2 49 Humidification sensor 8 Magnet of counter component cover 28 Heat exchanger co...

Page 18: ...ut other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment auth...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: