background image

2

EN

dehumidifier TTR 50 E

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 5

Transport and storage........................................................... 6

Assembly and start-up.......................................................... 6

Operation ............................................................................... 8

Errors and faults.................................................................. 11

Maintenance ........................................................................ 12

Technical annex................................................................... 15

Disposal ............................................................................... 18

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TTR 50 E

https://hub.trotec.com/?id=46714

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged 
from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Only put up the device in an upright, stable position on firm
ground.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Do not cover the device during operation.

Do not sit on the device.

This device is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Summary of Contents for TTR 50 E

Page 1: ...TRT BA TTR50E TC220609TTRT01 001 EN TTR 50 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...ways store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in ele...

Page 3: ...igns stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose...

Page 4: ...electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable o...

Page 5: ...ndensate can be discharged via a condensation hose connected to the connection opening The drier air thus conditioned is fed back to the room air via the air outlet The drier air mixes with the air in...

Page 6: ...wer cable out of the mains socket When the device is not being used observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an...

Page 7: ...iving rooms a relative humidity of approx 50 to 60 is sufficient In storage facilities and archives the humidity should not exceed approx 50 Inserting the air filter Note Do not operate the device wit...

Page 8: ...speed is set 21 Speed button Setting the fan speed 22 Run LED Is illuminated in green when the device has been switched on No Designation Meaning 23 Full LED Is illuminated when the condensation tank...

Page 9: ...Press the Swing button 10 The Swing LED 9 is illuminated The swing function is activated 2 Press the Swing button 10 again to deactivate the swing function The Swing LED 9 goes out Setting the timer...

Page 10: ...e hose must not be kinked Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Press the On Off button 24 Wait for 4 minutes Due to the rundown time of the interna...

Page 11: ...ondensation tank for dirt If necessary clean the condensation tank The float must be able to move freely Check the room temperature and the current room humidity level If the current room humidity lev...

Page 12: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 13: ...ol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the insi...

Page 14: ...condensation tank 5 over a drain or sink 4 Rinse the condensation tank 5 with clear water Clean the condensation tank 5 at regular intervals using a mild cleaning agent no detergent 5 Reattach the cov...

Page 15: ...pter Technical annex Technical data Parameter Value Model TTR 50 E Max dehumidification performance 7 5 l 24 h Dehumidification performance 30 C and 80 RH 7 l Amount of air 126 m h Operating range tem...

Page 16: ...16 EN dehumidifier TTR 50 E Wiring diagram...

Page 17: ...cover A 2 47 Anti fall switch 6 Gear 1 26 Rubber sac 48 Motor capacitor 7 Shield electrode 27 Heat exchanger cover B 2 49 Humidification sensor 8 Magnet of counter component cover 28 Heat exchanger co...

Page 18: ...ut other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment auth...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...