background image

20L Dehumidifier

For Customer Services & Spare Parts please call

0345 209 7461

Or visit us at

https://mda.russellhobbs.com

PLEASE RETAIN

FOR FUTURE REFERENCE

Model Number: RHDH2002

220-240V AC 50Hz 440W

Summary of Contents for RHDH2002

Page 1: ...20L Dehumidifier For Customer Services Spare Parts please call 0345 209 7461 Or visit us at https mda russellhobbs com PLEASE RETAIN FOR FUTURE REFERENCE Model Number RHDH2002 220 240V AC 50Hz 440W ...

Page 2: ... Panel Diagram 6 Positioning your Dehumidifier 7 Using your Dehumidifier 8 14 Emptying your Dehumidifier 14 15 Cleaning and Care 16 17 Troubleshooting 18 Guarantee and Customer Services 19 Spare Parts 20 Connection to the Mains Supply 21 Notes 22 Specification 23 CONTENTS Page 2 ...

Page 3: ...ors or extension leads when connecting the appliance to the electrical power supply Do not plug in if the plug is damaged Do not pull twist or damage the power cable Do not plug in or un plug the appliance with wet hands to prevent electrical shock Always store the unit in an upright position in order to maintain the compressor working in a proper condition Never insert your finger or any other ob...

Page 4: ...late This product is designed to operate on 220 240V AC 50Hz Connection to any other power source may damage the unit This product may be fitted with a non re wireable plug If it is necessary to change the fuse in the plug the fuse cover must be refitted If the fuse cover becomes lost or damaged the plug must not be used until a suitable replacement is obtained If the plug has to be changed becaus...

Page 5: ...isit us at https mda russellhobbs com Front 1 Control panel 2 Air outlet grille 3 Water tank 4 Water tank window 5 Handle 1 2 3 5 7 10 8 Rear 6 Drain hose outlet 7 Air inlet grille 8 Air filter behind the air intake grille 9 Power cord buckle 10 Power cord 11 Castor Page 5 4 9 6 11 ...

Page 6: ...ion mode indicator light 1 2 3 4 5 6 7 8 Page 6 10 9 Continuous dehumidifier extraction mode indicator light 10 Dryer mode indicator light 11 Water tank full indicator light 12 LED Display 13 Medium fan speed indicator light 14 Low fan speed indicator light 15 Timer indicator light 15 9 11 12 13 14 when both indicator lights are illuminate then the High fan speed has been selected ...

Page 7: ... for good air circulation Allow at least 40cm of air space above the unit for good air circulation Place the unit in an area where the temperature will not fall below 5 C 41 F The coils can become covered with frost at temperatures below 5 C 41 F which may reduce performance Place the unit away from clothes dryers heaters or radiators The dehumidifier must be operated in an enclosed area to be mos...

Page 8: ...ue to run to remove the frost Once the frost is removed the compressor will operate again If power to the unit is broken unexpectedly power cut once power is restored the unit will restart on the function it was running prior to the power being broken Turning the Unit On Remove all packaging and plug the unit into a socket Ensure the water tank is correctly positioned the drain plug is in place in...

Page 9: ... dehumidifying mode the unit will automatically control room humidity in a comfortable range 45 55 according to the room temperature Press the Mode button until the SMART indicator light is illuminated Press the Power button or Mode button to cancel the Smart Dehumidification Extraction Mode Note The humidity cannot be set when the unit is operating Smart Dehumidification Extraction Mode Dryer Mod...

Page 10: ... Humidity in 5 increments decrements by pressing the and keys To select the desired humidity level ensure the unit is not on the continuous mode This can be done by checking the CONT indicator is not illuminated If it is then simply press the CONT button to de activate the continuous mode and the CONT indicator will switch off Use the Up and Down control buttons to select the desired humidity The ...

Page 11: ...et when the unit is ON Press the Timer button until the Timer Off indicator is illuminated Use the up and down controls to select the desired end time The stop time can be adjusted in 0 5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours The selected time will stay on the display for 5 seconds and will then disappear The Auto Stop time can be viewed by pressing the Timer ...

Page 12: ... the fan speed to High to obtain the maximum moisture removal When the humidity has been reduced and quiet operation is preferred night time for example you can set the fan control to Medium or Low The humidity level can be set when the fan speed has been selected however the extraction rate will be lower if Low or Medium fan speed has been selected ...

Page 13: ...s full When the water tank is removed When the water tank is not replaced in the proper position 3 Minute Restart After the unit has stopped it cannot be restarted for 3 minutes This is to protect the unit Operation will automatically start after 3 minutes Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disapp...

Page 14: ...leakage detection With this new technology the display area will appear EC when the unit detects refrigerant leakage call customer service EMPTYING YOUR DEHUMIDIFIER There are two ways to remove collected water Collection in the Water Tank When the water tank is full the unit will automatically stop running and the Full indicator light will illuminate Slowly pull out the tank and grip the left and...

Page 15: ...r drain by attaching the unit with a inner diameter 13 5mm hose Remove the rubber bung from the Drain Hose Outlet on the back of the unit Attach the hose into the Drain Hose Outlet in the back of the unit as shown below Lead the water hose to a suitable drainage facility The drainage facility should be lower than the drain outlet of the unit Be sure to run the water hose sloping downward and let t...

Page 16: ...th tabs on the Air Inlet Grille upwards Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher To Replace the Air Filter Insert the top of the Air Inlet Grille Filter into the unit then click the bottom tabs into place CAUTION DO NOT operate the dehumidifier without a filter This will cause dirt and lint to build up and clog ...

Page 17: ...very few weeks clean the tank to prevent growth of mould mildew and bacteria Partially fill the tank with clean water and add a little mild detergent Swish it around in the tank empty and rinse NOTE Do not use a dishwasher to clean the tank After clean the tank must be in place and securely seated for the dehumidifier to operate When not using the unit for long time periods After turning off the u...

Page 18: ...or furniture blocking the front or back of the dehumidifier The humidity selector may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 50 C 410 F There is a kerosene heater or something giving off water vapour in the room The unit makes a loud sound when operating The air filter is clogged The unit is tilted instead of upri...

Page 19: ...ent is at the discretion of the retailer The following conditions apply The product must be returned to the retailer with the original proof of purchase The product must be installed and used in accordance with the instructions contained in this instruction guide and any other instructions for use which are supplied It must be used for domestic purposes only and for its intended use This warranty ...

Page 20: ...call 0345 209 7461 Or visit us at https mda russellhobbs com To check the availability of the following spare parts simply contact our friendly Customer Services team using the details provided at the bottom of this page Air Filter Drain Hose Bung Page 20 ...

Page 21: ...uct corresponds with your supply voltage How to change the fuse 1 Slot the end of a screwdriver into the recess in the fuse holder of the plug 2 Pull the fuse holder upwards until free of the plug and slide the fuse out 3 Replace the fuse and replace fuse holder pushing down until locked into place Important Only ever use a 13 amp fuse Page 21 ...

Page 22: ...NOTES Page 22 ...

Page 23: ...ion Page 23 Model RHDH2002 Voltage 220 240V 50Hz Power Input 440W Moisture Removal 20L per day DB 300C RH 80 Refrigerant R290 75g Overall Size D x W x H 24 5cm 35cm 51cm Operating Temperature 50C 350C Weight 15Kg ...

Page 24: ...or the recovery and recycling of materials contained within Your co operation is vital to ensure the success of these schemes and for the protection of the environment For your nearest disposal facility visit www recycle more co uk or ask in store for details We reserve the right due to possible changes to design to alter the instruction manual without prior notice For Customer Services Spare Part...