Dryer/Fan/Seat Temperature
Fault
Failure Analysis
Solutions
Drying with
cold air
Check the fan temperature
setting if it’s off or low
Adjust the fan temperature
according to the manual
Seat is not
warm enough
Check the seat temperature
setting if it’s off or low
Adjust the seat temperature
according to the manual
Remote Failure
Fault
Failure Analysis
Solutions
Remote not
working
Low battery
Replace the old battery
Check if there’s any water
inside the remote
Dry the remote with a dry
cotton cloth
Toilet
Fault
Failure Analysis
Solutions
Unclean flush
when the water
pressure is low
Angle valve filter blocked
Clean the filter according to
the manual
Too low water pressure
Measure if the water volume
is 10L per 30s or not (buy a
booster pump)
Bended water inlet pipe
Ensure that the water supply
line is not kinked
Normal water
pressure but
flush is unclean
and has no
siphon
Outlet has air leakage
Consult a professional repair
man
S-pipe is blocked
Use a toilet dredge
Normal water
pressure but
flush is not
working
Check if the angle valve is
closed or not
Open the angle valve
Flush valve failure
Consult a professional repair man