TrojanTwo User Guide v3.8
Page | 55
13.2.4
Shutdown
13.2.5
Exporting statistics data to a CSV file
Statistics data from HOME -> Statistics menu can be exported and saved into a CSV file from a user PC
which is connected to the same network as the TrojanTwo.
Actual IP address of the TrojanTwo press can be set or acquired at HOME -> Settings -> Network
menu (see section 13.2.2 for network settings)
Current IP address displayed at HOME\Settings\Network menu
NOTE:
IP address on screenshot above is an example only. Actual IP address is local network
dependent and can always be checked at HOME -> Settings -> Network menu
CAUTION:
Always wait until shutdown process finishes before
shutting down the power supply! Otherwise the
Maintenance Module inside the machine might end
up in the wrong position and cannot protect the
printhead from dehydration. Dehydration of nozzles
in the printhead may result in print quality defects.
Shutdown process may take 1-2 minutes.
Shuts down the TrojanTwo press completely.
NOTE:
When shutting down the unit it is advised
to wait with turning the power switch off until the
shutdown process is finished. There is a message
on the display when the shutdown process is
initiated to indicate that the shutdown process is
still going on.
NOTE:
When shutdown process is finished (the
screen turns blank) it is advised to turn the
physical power switch off. The power switch is
located at the back of the TrojanTwo press.